Brand:

Caprari E6NVX and E8NVX 6 and 8 Inch Stainless Borehole Pumps

Description

Stainless 6 and 8 inch borehole pumps for water wells

The Caprari E6NVX and E8NVX series are electric borehole pumps for 6 inch and 8 inch wells, built with stainless steel hydraulics and driven by Caprari submersible motors on 2 poles at 50 Hz. The catalogue (code 998937B/05-26) covers six hydraulic sizes, E6NVX17, E6NVX30, E6NVX46, E6NVX60, E8NVX77 and E8NVX95, each in many stage counts, paired with MAC or MPC submersible motors. In their standard construction the pumps are suitable for chemically and mechanically non-aggressive water.

Pump components in the materials list are stainless steel (valve casing, conical valve, shaft, shaft sleeve, impeller, diffuser, cable guard, coupling, suction support and strainer), with rubber shaft bearing bushes and stainless steel bolts and nuts. The catalogue lists a Defender item in the construction drawing. Performance is stated for 400 V powered motors, cold water at 15 C and atmospheric pressure, guaranteed to UNI/ISO 9906 Grade 3B, with Grade 2B testing on request.

Technical specification

Parameter Specification
Series and sizes E6NVX17, E6NVX30, E6NVX46, E6NVX60 (6 in); E8NVX77, E8NVX95 (8 in)
Poles and frequency 2 poles, 50 Hz
Standard supply Three-phase 400 V direct starting for all power outputs (MAC/MPC …-8 motors); 400/700 V on the …-9 motors
Motor power limits 6 in: MAC and MPC up to 37 kW; 8 in: MAC up to 110 kW, MPC up to 92 kW
Maximum submersion of motor 150 m
Maximum liquid temperature at the motor (water speed over jacket above 0.5 m/s) MAC6 30 C; MPC6 30 C; MAC8 30 C; MPC8 25 C
Maximum solids content 50 g/m3, of the hardness and granulometry of silt
Maximum running time with outlet closed and pump submerged 3 minutes
Voltage tolerance 230 V and 400 V plus or minus 10%; other voltages and frequencies plus or minus 5%
Inverter operation All motors suitable, with a filter between inverter and motor to limit the voltage gradient
Pump efficiency index M.E.I. 0.40 or higher on the listed models
Orientation Vertical; special execution for horizontal installation on request
Thermal probes On request

Hydraulic sizes at a glance (from the operating data and dimension tables)

Hydraulic Outlet Stages Motor power, kW Flow axis up to, m3/h Shut-off head, m (fewest to most stages) Weight, kg
E6NVX17 Rp 2 1/2 6 to 40 4 to 22 25.2 65 to 428 52.3 to 136.4
E6NVX30 Rp 3 4 to 35 4 to 30 43.2 44.5 to 383 53.5 to 168.3
E6NVX46 Rp 3 3 to 25 5.5 to 37 54 42 to 343 57 to 176.8
E6NVX60 Rp 4 2 to 21 4 to 37 81 29.5 to 299 50.6 to 169.2
E8NVX77 Rp 5 1 to 20 4 to 75 99 19 to 387 59.2 to 337.1
E8NVX95 Rp 5 1 to 20 5.5 to 92 126 21 to 429 64.1 to 365.7

The ranges are derived from the printed tables; maximum pump outside diameter is 145 or 146 mm for the 6 in models and 180 mm for the 8 in models. Weights are for pump plus motor combinations listed in the dimension table.

Reading the code and choosing a model

The code E6NVX17-6/8-W reads: E.NVX series, 6 inch nominal diameter, hydraulic identification number 17, motor coupling flange -6, 8 stages, and -W for a unit used at 50 or 60 Hz. A complete pump adds the motor, for example E6NVX17/8+MAC67A-8V, where MAC is the submersible motor, 6 the nominal diameter in inches, 7 the nominal power in CV, and -8 the construction feature code.

Pick the hydraulic by flow first: the E6NVX17 suits flows up to about 25 m3/h on the table, while the E8NVX95 table runs to 126 m3/h. Then choose the number of stages to deliver the head, remembering that the catalogue head includes friction losses in the check valve for radial pumps but that, for mixed-flow pumps, the valve losses must be deducted from the listed head. The next step is the motor: check that its power covers the duty point and that cable section and length, voltage drop and generator size are within the cable and generator tables included in the catalogue.

  • Confirm the well diameter against the pump diameter (145, 146 or 180 mm maximum).
  • Check water temperature and sand content (50 g/m3 maximum) against the stated limits.
  • Provide for a minimum water speed past the motor jacket for cooling.
  • Specify the check valve, cable and any accessories listed on the catalogue accessories pages.

Uses, limits and what to confirm

Borehole pumps of this size supply municipal wells, farm and landscape irrigation, industrial water and desalination feed or camp water supply across Oman and the GCC. The catalogue limits are firm: 50 g/m3 solids, 30 C at the motor cooling, and 3 minutes on a closed outlet. Where water is more aggressive, sandy or hotter than those limits, ask Caprari about other series, because this catalogue describes only the standard construction.

No ATEX, fire-pump, drinking-water or marine approval is printed on the cover pages of this catalogue for the E6NVX and E8NVX, so none is claimed. The catalogue also provides the motor material list, dynamic momentum values, feeding cables and maximum current and length tables, generator power and reactive power compensation tables, which a pump engineer should use for the sizing.

Selection and installation notes

A borehole pump must be matched to the well: confirm the casing diameter, the pumping water level, the depth of installation, the sand content and the water quality before ordering. Keep the motor submerged and above the well bottom, use a cooling sleeve where the manual asks for one, protect the motor with the right starter and cable and start the pump against a throttled valve until the water runs clear.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Documents, related items and quotation

The official Caprari catalogue is attached. Other pumps are listed under pumps. Seven Star LLC is an independent supplier in Muscat; send the well diameter, depth, static and dynamic levels, flow and head, and the water analysis, and we will confirm the hydraulic, stage count and motor against the Caprari catalogue before quoting.

Datasheets & Documents
  • PDF Datasheet Caprari E6-E8 NVX borehole pump technical catalogue (EN/FR/IT, 05-26) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Caprari is an Italian pump manufacturer, founded in 1945 by Amadio Caprari as Idromeccanica Caprari and headquartered in Modena. By 1950 it was building vertical lineshaft pumps, in 1968 it produced its first submersible deep-well pump, and from the 1970s it opened subsidiaries abroad. The Italian investment firm Ambienta acquired Caprari in February 2021.

Seven Star LLC is an independent supplier in Muscat. We list Caprari pumps for water utilities, farms, contractors and industry in Oman and the GCC.

Caprari company profile

Founded 1945, Italy, by Amadio Caprari
Headquarters Modena, Italy
Ownership Ambienta, since February 2021
Production Plants in Italy, China and Turkey
Product families NMC and NC.E EN 733 end-suction pumps, MEC-MG flanged pumps for diesel drives, E6 and E8 stainless borehole pumps, Desert sand-resistant submersible pumps, D-M drainage and sewage pumps, CVD vertical multistage pumps

Milestones

  • 1945: Amadio Caprari founds Idromeccanica Caprari.
  • 1965: The current Modena headquarters opens.
  • 1968: Caprari builds its first submersible deep-well pump.
  • 2021: Ambienta acquires Caprari.

Caprari product series

Borehole pumps include the E6NVX and E8NVX 6 and 8 inch stainless steel pumps and the Desert E4X and E6X sand-resistant pumps. Surface pumps include the NMC and NMCS monobloc EN 733 pumps from DN32 to DN150, the NC.E end-suction pumps for fire-fighting units, the PM high pressure horizontal multistage pumps, the CVD vertical multistage pumps and the SCC double-suction split case pumps from DN100 to DN700.

The P Series P6P and P8P are vertical lineshaft pumps, the MEC-MG, MEC-AG and BHG pumps are flanged for diesel engine drive, and the D-M Series covers submersible drainage and sewage pumps.

Where Caprari pumps are used

Well fields and water supply, farm irrigation, pressure boosting, fire-fighting pump sets, drainage of sites and basements, and sewage lifting.

Caprari products we list

Family Examples
Pumps CVD Vertical Multistage Electric Pump, D-M Series Submersible Drainage and Sewa…, Desert E4X and E6X Sand-Resistant Boreho…, E6NVX and E8NVX 6 and 8 Inch Stainless B…, MEC-MG, NC.E EN 733 End-Suction Pumps for Fire-F…, NMC and NMCS Monobloc EN 733 Pumps

Ordering Caprari pumps: what we need

Send the model or the required flow and head, the liquid, borehole diameter or installation type, power supply and motor or engine drive.

Facts checked against Caprari's own history page and Ambienta's 2021 announcement, October 2026.

Frequently Asked Questions

What does E6NVX17/8+MAC67A-8V mean?
E.NVX series, 6 in, hydraulic 17, 8 stages, with a MAC submersible motor of 6 in diameter and 7 CV nominal power; -8 is the motor construction code.
What is the maximum solids content?
50 g/m3 of the hardness and granulometry of silt, for the standard construction.
How deep can the motor be submerged?
The motor general remarks state a maximum submersion of 150 m.
Can the pumps run on an inverter?
Yes, all motors are suitable for inverter operation with a filter between inverter and motor to limit the voltage gradient.
How long can the pump run with a closed outlet?
A maximum of 3 minutes with the outlet closed and the pump submerged.