Brand:

Micro Motion High Pressure Coriolis Flow Meters HPC015 and HPC020

Description

Coriolis metering for ultra-high-pressure injection and dispensing

The Micro Motion High Pressure Coriolis (HPC) meter is designed for ultra-high-pressure duty, up to 16,401 psi (1,131 bar) on the largest model. The datasheet names chemical injection in oil and gas and hydrogen dispensing as typical uses. It has no moving parts and needs no special mounting or flow conditioning, and it can be supplied with MVD Direct Connect technology that removes the need for an external transmitter where space and weight are limited.

Technical specifications

Parameter Specification
Datasheet PS-002073, Rev G, April 2025
Models HPC015M, HPC015N, HPC015P (1/8 in, DN3, XM-19 stainless steel); HPC015H (1/8 in, nickel alloy N06022); HPC020M, HPC020N (1/6 in, DN3, XM-19)
Maximum operating pressure HPC015M 6,991 psi (482 bar); HPC015N 13,960 psi (963 bar); HPC015H 15,622 psi (1,077 bar); HPC020M 12,168 psi (839 bar); HPC020N 16,401 psi (1,131 bar); HPC015P about 1,060 bar
Liquid mass and volume flow accuracy ±0.10% of rate (premium option); 0.20% of rate (standard option)
Liquid repeatability 0.05% of rate (premium); 0.10% of rate (standard)
Liquid density accuracy ±1 kg/m3 (±0.001 g/cm3); repeatability 0.5 kg/m3
Gas accuracy ±0.5% of batch; repeatability 0.25% of batch
Temperature accuracy ±1 °C ±0.5% of reading
Nominal flow rate HPC015M/N/P 176 kg/h; HPC015H 155 kg/h; HPC020M 540 kg/h; HPC020N 462 kg/h
Maximum flow rate HPC015 360 kg/h; HPC020M 960 kg/h; HPC020N 840 kg/h
Zero stability HPC015 0.024 kg/h; HPC020 0.063 kg/h
Process temperature -50.8 °F to 392 °F (-46 °C to 200 °C)
Ambient temperature -40 °F to 140 °F (-40 °C to 60 °C)
Process fittings 9/16 in (15 mm) female medium-pressure cone and thread, autoclave compatible
Case Rupture disk fitted as a standard option; 316L disk, burst pressure 63.8 psig (4.4 barg)
Sensor weight 13 lb (5.9 kg) with 9/16 in autoclave connections
Standards ASME B31.3 high-pressure piping requirements, PED 2014/68/EU, SAE J2601-1, OIML R139-1 for custody transfer; CSA, ATEX and IECEx approvals

Transmitters and installation

HPC meters are offered with MVDSolo, 1500, 1700, 2200, 2400, 2500, 2700, 4200 and 5700 transmitters, giving single or multivariable outputs with milliamp, pulse, dual pulse or digital signals and an integral display. The rupture disk vents process fluid if a tube fails, so the sensor must be oriented and piped so that personnel and equipment are never exposed to the discharge path, and the disk must stay installed to keep the Ex-i certification and IP rating. See the Micro Motion 5700 for an advanced transmitter option.

Temperature and pressure effects are small. The datasheet gives a process temperature effect on mass flow of ±0.0009 percent of maximum flow per °C for HPC015M, N and P, ±0.00175 for HPC015H and ±0.002 for HPC020M and N. There is no process pressure effect on mass flow accuracy up to the maximum pressure rating, and the density pressure effect on the HPC015 is 0.000001 g/cm3 per psi (0.001 kg/m3 per bar).

What to confirm before ordering

  • Maximum and normal operating pressure against the model rating, including pressure spikes
  • Fluid, flow range and temperature, and whether hydrogen or injection chemical service applies
  • Fitting adapter size (9/16 in or 3/8 in) and wetted material (XM-19 or nickel alloy)
  • Transmitter, mounting and output type, and hazardous area approval
  • Whether the rupture disk should be fitted or omitted

How the Micro Motion HPC works

The fluid flows through tubes that are made to vibrate. The mass flow bends the tubes slightly, and sensors read the twist. The twist gives the mass flow directly, and the tube frequency gives the density. The meter has no moving parts and needs no flow conditioning.

Where the Micro Motion HPC is used

  • Chemical injection in oil and gas
  • Hydrogen dispensing
  • High-pressure dosing
  • Test rigs
  • Compact skids with limited space

Selection checklist for the Micro Motion HPC

  • Model HPC015 or HPC020
  • Wetted material
  • Maximum operating pressure
  • Flow rate
  • Accuracy option
  • Process temperature
  • Transmitter type
  • Process connection

Installation, commissioning and maintenance notes for the Micro Motion HPC

Fit the sensor on the line with the 9/16 inch autoclave connections. Support the pipe so the sensor carries no stress. Connect the transmitter or the Direct Connect electronics. Zero the meter with the flow stopped and the tubes full. Check the zero at each service.

Requesting a quotation for the Micro Motion HPC

Please send the model, the pressure, the flow and the transmitter needed. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

Micro Motion HPC models

The models are the HPC015M, HPC015N, HPC015P, HPC015H, HPC020M and HPC020N.

Micro Motion HPC maximum pressure

The largest model reaches 16,401 psi, or 1,131 bar.

Micro Motion HPC liquid accuracy

The premium option gives plus or minus 0.10 percent of rate.

Micro Motion HPC density accuracy

The density accuracy is plus or minus 1 kg/m3.

Micro Motion HPC gas accuracy

The gas accuracy is plus or minus 0.5 percent of the batch.

Micro Motion HPC flow rate

The maximum flow is 360 kg/h on the HPC015 and up to 960 kg/h on the HPC020M.

Micro Motion HPC process temperature

The process range is minus 46 to plus 200 degrees C.

Micro Motion HPC process fittings

The fittings are 9/16 inch female cone and thread, autoclave compatible.

Micro Motion HPC rupture disk

A rupture disk of 316L is fitted as a standard option.

Micro Motion HPC weight

The sensor weighs 5.9 kg with its connections.

Meter records for the Micro Motion HPC

Record the model, the zero value and the date of each check.

Choosing the right Micro Motion HPC model

Choose the model from the working pressure first, and then from the flow rate.

Documents and quotation

The Micro Motion High Pressure Coriolis datasheet (PS-002073 Rev G, April 2025) is available from the product documents on this page. Seven Star LLC is an independent supplier in Muscat; send the complete order code from the nameplate or your specification and we will check it against the manufacturer documentation before quoting. Browse more flowmeters in the catalogue.

Datasheets & Documents
  • PDF Datasheet Micro Motion High Pressure Coriolis datasheet PS-002073 Rev G (April 2025) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Coriolis flow and density meters have carried the Micro Motion name since 1977, when the company started in Boulder, USA. A Coriolis meter measures mass flow directly and reads density from the same tubes. Seven Star LLC, an independent supplier in Oman, lists the Micro Motion ELITE CMF400 Coriolis flow and density meter and the compact G-Series, and sources Micro Motion flow meters by complete model code.

Micro Motion meter families

ELITE is the manufacturer's top performance family for flow and density, and the CMF400 is one of its larger line sizes. The G-Series is a newer, very compact family for general duty. Each sensor is paired with a Coriolis transmitter, and the range also includes density and viscosity meters. Liquids, gases and slurries can all be measured, which is why these meters appear in oil and gas, refining, chemical, food and marine service.

Ordering Micro Motion meters: what we need

A Micro Motion sensor and its transmitter each have their own model code and serial number; send both. For a new meter we need the fluid, flow range, density, viscosity, operating pressure and temperature, line size, process connection and rating, wetted material, hazardous area approval, outputs and protocol. Custody transfer duty in the GCC should be stated up front because it changes the approvals and calibration options requested.

Frequently Asked Questions

What pressure can the HPC meter handle?
Maximum operating pressure depends on the model, from 6,991 psi (482 bar) for HPC015M up to 16,401 psi (1,131 bar) for HPC020N.
What applications does the datasheet name?
Chemical injection in the oil and gas industry and hydrogen dispensing, among other ultra-high-pressure uses.
What accuracy does it offer?
Liquid mass and volume flow accuracy is ±0.10% of rate for the premium option and 0.20% for the standard option, with ±1 kg/m3 density.
What are the process connections?
Female 9/16 in (15 mm) medium-pressure cone and thread connections, autoclave compatible, with adapters to 3/8 in available as options.
Why does the sensor have a rupture disk?
The standard disk vents process fluid in the unlikely event of a tube breach; the sensor must be oriented so the discharge path is safe.