Brand:

APC SCL500RMI1UNC Smart-UPS Line Interactive 500VA Lithium-ion

Description

What the SCL500RMI1UNC provides

The APC SCL500RMI1UNC is an uninterruptible power supply from the Smart-UPS range, rated at 500 VA (400 W) with line interactive topology.

It is fed from 230 V AC 1 phase and supplies 230 V AC 1 phase as a sine wave. The listed battery type is li-ion (lithium-ion) internal included. The recorded mounting mode is rack-mounted.

The APC SCL500RMI1UNC is listed with line interactive topology. A line-interactive design corrects normal mains variations with automatic voltage regulation and switches to battery power when the supply fails. It is commonly used for servers, networking equipment and workstations where sags, surges and short outages are the main concern.

The output waveform is listed as sine wave. A sine-wave output is the safer choice for equipment with active power factor correction and for sensitive electronics. The listed ratings of 500 VA and 400 W correspond to a power factor of 0.8. Size the load against the watt rating as well as the VA rating, and keep margin for future equipment.

Technical specifications

Parameter Specification
Part number SCL500RMI1UNC
Main input voltage 230 V AC 1 phase
Input connection IEC 60320 C14
Input protection Circuit breaker
Input frequency 50/60 Hz +/- 3 Hz auto sensing
Output voltage 230 V AC 1 phase
Rated power in W 400 W
Rated power in VA 500 VA
Output connection 4 IEC 60320 C13
Harmonic distortion Less than 5 %
Maximum configurable power in VA 500 VA
Maximum configurable power in W 400 W
Transfer time 6 ms typical : 10 ms maximum
UPS topology Line interactive
Waveform type Sine wave
Output frequency 50/60 Hz +/- 3 Hz sync to mains
Battery type Li-Ion (Lithium-Ion) internal included
Control panel LED status display with on line : on battery : replace battery and building wiring fault
Free slot 0
Preinstalled device Network management card 3
Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
UPS connectivity Serial port / USB port / Embedded network management card 3
Surge energy rating 510 J
Noise filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Number of rack unit 1U
Color Black with silver front bezel
Height 44 mm
Width 432 mm
Depth 232 mm
Product weight 4.1 kg
Mounting preference No preference
Mounting mode Rack-mounted
USB compatible Yes
Provided equipment Installation guide / Rack mounting support rails / USB cable
Redundant No
Range of product Smart-UPS
Product or component type Uninterruptible power supply (UPS)
Battery type Li-Ion (Lithium-Ion)
Battery graph comment This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v
Extendable runtime 0
Battery design life 8…10 year(s)
Battery charging power 10 W rated
Product certification C-Tick / CE / EAC / UK PSTI
Equipment protection policy Lifetime : $150000
Standard EN/IEC 62040-2:2006/AC:2006 / EN/IEC 62040-2:2018
Ambient air temperature for operation 0…40 °C
Ambient air temperature for storage -15…45 °C
Storage altitude 0…7620 m
IP protection IP20
Relative humidity 0…95 % non-condensing
Storage relative humidity 0…95 % non-condensing
Acoustic level 45 dBA
Heat dissipation 41.61 Btu/h
Operating altitude 0…10000 ft
Warranty (in months) 60

Output, input and battery information

Output connections: 4 IEC 60320 C13. Input connection: IEC 60320 C14. Input frequency: 50/60 Hz +/- 3 Hz auto sensing. Communication and expansion: Serial port / USB port / Embedded network management card 3.

Load sizing should be checked against both the VA and the watt rating, and runtime depends on the connected load, battery condition and ambient temperature. Confirm these points against the product documents before ordering.

Installation space and operating limits

Dimensions are 44 mm x 432 mm x 232 mm (H x W x D), and the unit weighs 4.1 kg. Colour: black with silver front bezel.

Listed operating limits: operating temperature 0…40 °C; relative humidity 0…95 % non-condensing; operating altitude 0…10000 ft; protection IP20; acoustic level 45 dBA.

Certifications: C-Tick / CE / EAC / UK PSTI. Standards: EN/IEC 62040-2:2006/AC:2006 / EN/IEC 62040-2:2018. Warranty recorded by APC (months): 60.

Battery data listed for this model: type li-ion (lithium-ion) (internal battery included). Lithium-ion batteries are generally lighter and longer-lived than sealed lead-acid blocks, and the battery state can be monitored through the UPS management interface. Used batteries must be recycled according to local regulations.

Further electrical values recorded for the APC SCL500RMI1UNC include: transfer time: 6 ms typical : 10 ms maximum; surge energy rating: 510 J. Use these figures when sizing upstream protection and cabling, and confirm them against the installation documents for the exact variant.

Communication and management details listed: UPS connectivity: Serial port / USB port / Embedded network management card 3. Network cards, software and monitoring options should be matched to the facility monitoring system before ordering.

The mounting mode is listed as rack-mounted. The unit measures 44 mm x 432 mm x 232 mm (H x W x D) and weighs 4.1 kg, so check the available space and the floor or rack loading before delivery. It occupies 1U of rack space. Rack installation should be checked against the rack depth, rail kit and the clearance needed behind the unit for cables and airflow. Listed environmental limits: operating temperature 0…40 °C; relative humidity 0…95 % non-condensing; altitude 0…10000 ft. Equipment rooms in the Gulf region often run warm, so leave ventilation clearance and keep the unit away from direct heat sources.

Certifications listed: C-Tick / CE / EAC / UK PSTI. The warranty period recorded in the product data is 60 months. If a project requires certificates or test reports, include that request with the quotation request.

The SCL500RMI1UNC within the APC Smart-UPS range

Smart-UPS is the APC range most often found under servers, network switches, storage and branch-office IT. The line-interactive models correct everyday voltage swings with automatic voltage regulation instead of draining the battery, and transfer to battery within milliseconds when the supply fails. Many units carry a SmartSlot for a network management card, so the UPS can be monitored over the network and can trigger an orderly shutdown of connected servers through PowerChute software.

The APC SCL500RMI1UNC is a complete UPS rather than a spare part, so the selection starts from the load. Add up the real power of the connected equipment in watts, compare it with the watt rating of the UPS as well as the VA rating, and keep about 20 to 25 percent margin for growth and for inrush current when equipment restarts. Then define the runtime the site needs: a few minutes is enough to ride through short interruptions or to let a standby generator start and stabilise, while longer outages call for external battery capacity where the model supports it.

In the product data for the APC SCL500RMI1UNC, it is rated 500 VA and 400 W; it uses line interactive topology; its battery technology is listed as li-ion (lithium-ion) internal included; it occupies 1U rack unit(s). These values are the starting point for matching it to the rest of the installation.

Using the SCL500RMI1UNC in Gulf climate and grid conditions

Check the nominal voltage of the site against the input and output ratings in the specification table: Oman uses 240 V single-phase and 415 V three-phase at 50 Hz. Because it is listed for both 50 Hz and 60 Hz, the same model can be used on the 50 Hz grids of Oman, the UAE and Qatar and on the 60 Hz grid of Saudi Arabia. The listed operating temperature tops out at 40 °C. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, so the equipment belongs in an air-conditioned room or cabinet rather than an open plant area. Battery temperature has the biggest effect on service life: as a rule of thumb, the life of a valve-regulated lead-acid battery roughly halves for every 10 °C above 25 °C, so a room held at 20 to 25 °C pays back in fewer battery replacements.

The heat dissipation of 41.61 Btu/h has to be included in the cooling budget of the room. Fine dust inland and humid, salty air on the coast are hard on electronics, so a sealed room, clean filters and periodic inspection of fans and terminals are part of a reliable installation. Many sites in the region run the UPS downstream of a standby diesel generator. The UPS carries the load during the start-up of the generator and smooths its voltage and frequency, so the generator should be sized with margin for the UPS input and battery charging current.

What to send with an enquiry for the SCL500RMI1UNC

The following details help confirm compatibility before a quotation is issued:

  • The load to be protected in watts and VA, with the share of critical equipment
  • The runtime needed on battery, and whether a standby generator is installed
  • Input and output connection types required on site (IEC 60320 C14 / 4 IEC 60320 C13)
  • Rack or tower installation, and rack depth if rack-mounted
  • Whether a network management card or monitoring is required
  • The delivery location in Oman (for example Muscat, Sohar, Duqm or Salalah) or elsewhere in the GCC, and the required date

Browse the full APC catalogue or other Schneider Electric products supplied by Seven Star LLC.

Documents and quotation

The user guide for the SCL500RMI1UNC is hosted on this page under Documents so the wiring, installation and operating details can be reviewed before ordering.

The single-unit shipping package is listed as 16.8 cm (height) x 59 cm (width) x 33.7 cm (length) with a packed weight of 6.49 kg. Use these values when planning freight, lifting and receiving space.

To order, submit the part number SCL500RMI1UNC, the quantity and the delivery location. Related items are grouped under UPS and Batteries. Seven Star LLC is an independent supplier based in Muscat and answers with availability and a quotation.

Datasheets & Documents
  • PDF User guide APC SCL500RMI1UNC User guide Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

APC is Schneider Electric's brand for uninterruptible power supplies, power distribution units, cooling and racks for IT and control systems. American Power Conversion was founded in 1981 by three engineers from MIT's Lincoln Laboratory and grew into one of the largest UPS makers in the world. Schneider Electric completed its acquisition of APC on 14 February 2007, combined it with MGE UPS Systems, and since 2011 APC has been a product brand of Schneider Electric.
Seven Star LLC lists APC uninterruptible power supplies from desktop Back-UPS units to modular Symmetra systems, together with battery packs and network cards, and sources them for sites in Oman.

APC company profile
Founded1981, USA, as American Power ConversionFoundersThree engineers from MIT Lincoln LaboratoryOwnershipSchneider Electric since 14 February 2007; an APC by Schneider Electric product brand since 2011Product familiesBack-UPS, Easy UPS, Smart-UPS line-interactive, Smart-UPS On-Line SRT and SRV, Galaxy three-phase UPS, rack PDUs, NetShelter racks, network management cards and EcoStruxure IT software

Milestones
1981: American Power Conversion is founded by three MIT Lincoln Laboratory engineers.2006: Schneider Electric announces the acquisition of APC on 30 October.2007: The acquisition is completed on 14 February; APC is combined with MGE UPS Systems.2011: APC becomes a product brand within Schneider Electric.

APC UPS families on this page

APC names its UPS lines by topology and size:

Back-UPS and Back-UPS Pro: line-interactive units for workstations and small loads, such as BX1600MI-MS and BR1600MISmart-UPS: line-interactive models with sine wave output, including SMT750I, SMC1000IC and the Smart-UPS X SMX3000HV with its SMX120BP external battery packSmart-UPS SRT and Smart-UPS RT: online double-conversion units, for example SRT2200XLI, SRT3000XLI, SRT5KRMXLI and SURT8000XLIEasy UPS Online: SRV2KILSymmetra LX and Symmetra PX: modular, scalable systems for larger loads

The AP9641 Network Management Card 3 adds remote monitoring to UPS models with a SmartSlot.

Where APC UPS systems are used

In industrial plants across the GCC, APC UPS units back up DCS and PLC cabinets, operator stations, SCADA servers, telecom racks, fire and gas panels and analyzer shelters. Online double-conversion models are normally chosen for control systems because the load is always fed through the inverter. Line-interactive units suit office IT and less critical loads.

APC products we list
FamilyExamplesUPS and BatteriesAP9641 Network Management Card 3, BR1600MI Back-UPS Pro 1600VA/960W, BX1600MI-MS Back-UPS 1600VA Tower UPS, SMC1000IC Line-Interactive UPS 1000VA 600W, SMC1500I Smart-UPS C 1500VA/900W, SMT750I Smart-UPS 750VA/500W Line-Interactive, SMX120BP Smart-UPS X 120V External Battery, SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower and 9 more

Ordering APC UPS units and parts: what we need

Send the full SKU, for example SRT3000XLI, and not only the VA rating. The letters carry meaning: an I in the suffix marks a 230 V international model, XL an extended-run version that accepts external battery packs, and RM a rack-mount form. For a new requirement, give load in watts, input and output voltage, required runtime, tower or rack format, and the plug or hardwire arrangement. For batteries, send the UPS SKU and serial number so the correct replacement battery cartridge can be found in APC documentation.

Replacement batteries, battery packs and spares
Most APC service work is battery work. APC Replacement Battery Cartridges, sold under RBC and APCRBC numbers, are sets of sealed valve-regulated lead-acid blocks that arrive pre-wired with the connectors for the UPS models they are listed for, so a weak battery can be changed as one unit and, on hot-swap models, without switching the load off. Some newer cartridges carry an -LI suffix for lithium-ion versions. External battery packs extend runtime on XL and SRT models, and are chained to the UPS through the battery connector on the rear panel. To find the right cartridge, send the UPS SKU and serial number; the same UPS can use different cartridges across hardware revisions.
Modular and three-phase APC systems
Symmetra LX and Symmetra RM: single-phase modular UPS frames with hot-swappable power modules, battery modules and intelligence modules, so a failed module can be exchanged while the load stays on protected power.Symmetra PX: three-phase modular UPS for data rooms, built from power modules with N+1 redundancy and battery modules for runtime.Smart-UPS VT: three-phase double-conversion UPS for small data rooms and technical buildings.Silcon: large three-phase UPS based on delta conversion, still running in many plants and data centres; spare part kits are listed in levels (SPL1 to SPL4) so sites can hold the parts that match their service plan.Easy UPS On-Line (SRV): cost-focused double-conversion units, many with external battery pack support.
APC UPS in Oman and GCC conditions
Oman supplies 240 V single-phase and 415 V three-phase at 50 Hz, so international models with an I suffix (230 V nominal, adjustable to 240 V on most Smart-UPS units) are the usual choice. Heat is the main enemy: most APC UPS units are rated for operation up to 40 °C, while summer shade temperatures in Muscat and the interior pass 45 °C, and a lead-acid battery loses roughly half its service life for every 10 °C above 25 °C. Install UPS and batteries in a cooled room, keep filters clean in dusty inland sites, and size the standby generator with margin for UPS input and battery charging current.
All APC UPS systems, batteries and accessories on this site are grouped under UPS and Batteries, and the wider Schneider Electric range can be quoted together with them.

Facts checked against APC by Schneider Electric's published history, October 2026.

Browse APC products by category: UPS and Batteries.
Need a replacement battery for an APC UPS you already run? Use our APC UPS replacement battery finder to match the model to its official RBC cartridge.

Frequently Asked Questions

What is the rated power of the APC SCL500RMI1UNC?
The APC SCL500RMI1UNC is rated at 500 VA / 400 W and uses line interactive topology.
What input and output voltage does the APC SCL500RMI1UNC use?
The input is 230 V AC 1 phase at 50/60 Hz +/- 3 Hz auto sensing and the output is 230 V AC 1 phase.
What are the dimensions and weight of the APC SCL500RMI1UNC?
The listed dimensions are 44 mm x 432 mm x 232 mm (H x W x D) and the weight is 4.1 kg.
What operating conditions apply to the APC SCL500RMI1UNC?
Listed limits: operating temperature 0…40 °C; relative humidity 0…95 % non-condensing.
How can I request a quotation for the APC SCL500RMI1UNC?
Send the part number SCL500RMI1UNC with quantity and delivery location through the RFQ form. Seven Star LLC is an independent supplier in Muscat and replies with availability and a quotation.