Brand: Accuenergy
Accuenergy AcuDC-262 Dual-Channel DC Power and Energy Meter
Description
AcuDC-262 is a revenue-grade DC power and energy meter with one direct voltage input and two current inputs, so one unit can bill two DC outlets such as two EV charging ports. It meets IEC 62053-41 class 0.5, measures 12 to 1000 Vdc at 0.1 percent accuracy and communicates by Modbus RTU over RS485 and Modbus TCP/IP over Ethernet.
Two-outlet DC billing from a single instrument
The AcuDC-262 measures one DC voltage and two DC currents, each from a shunt or Hall effect sensor at 0.2 percent accuracy. Per-channel and total import, export, net and total energy and charge are kept, along with power, demand and ripple factor for voltage and each current.
Billing features include cable loss compensation, an electronic metrology seal that detects unauthorised configuration changes, and a tamper-proof physical seal. Three independent data loggers and one trend logger log at one-minute intervals for up to 16 months, with 16 MB onboard memory.
Features stated in the datasheet
- IEC 62053-41 class 0.5; complies with NIST Handbook 44 and the OCPP requirement of 0.1 Wh resolution.
- Meets or exceeds requirements for CTEP, NTEP, Eichrecht and LNE, and carries UL Recognized certification as printed.
- Extended voltage metering from 1000 V to 1200 V without specific accuracy requirements.
- LCD 256 x 64 pixel display; firmware statistics with timestamps for maximum and minimum values.
Technical specification
Metering (datasheet)
| Parameter | Specification |
|---|---|
| Voltage | 0.1 %; 0.01 V; 12.00 – 1000.00 V; update 20 ms and 100 ms |
| Current | 0.2 %; 0.001 A; sensor ranges: A1 -100 to 100 mV, A2 4 – 20 mA, A3 -5 to 5 V |
| Power | 0.5 %; 1 W; -9999.999 to 9999.999 kW |
| Energy | 0.5 %; 0.1 Wh; IEC 62053-41; to 999999999999.999 kWh |
| Charge | 0.5 %; 0.0001 Ah; update 100 ms |
| Current demand | 0.5 %; 0.001 A; 0 – 50000 A, configurable |
| Ripple factor | 0.001 %; 0 – 100 % |
Inputs, communication and environment
| Parameter | Specification |
|---|---|
| Current input pickup / accuracy | Irated x 0.1 %; 0.2 %; withstand 30 x Imax for 0.5 s |
| Voltage input | 0 – 1000 V; accuracy 0.1 % (12 V – 1000 V); withstand 5.0 kV RMS for 1 minute; pickup 10 V |
| DC control power | 12 – 48 V SELV; burden below 3 W |
| Communication | Modbus RTU via RS485 2400 – 115200 bps; Ethernet 10/100 BaseT Modbus TCP/IP |
| Operating / storage temperature | -25 to +70 C / -40 to +85 C; 0 – 75 % RH operation |
| Environment | Indoor and dry; altitude 0 – 2000 m; OVC II; pollution degree 2 |
| Dimensions and protection | 174.0 x 96.0 x 66.5 mm; IP30 – cabinet or enclosure of IP54 or higher recommended |
| Standards | IEC 62053-41; UL 61010-1, UL 61010-2-30; EMC EN55032 class A, FCC Part 15 class A |
Ordering code and sensors
The order code is Meter Model – Voltage Input – Current Input – Power Supply: AcuDC-262-1000V-A1-P2 (external 0 – 100 mV shunt), AcuDC-262-1000V-A2-P2 (4 – 20 mA Hall effect sensor) or AcuDC-262-1000V-A3-P2 (-5 to 5 V Hall effect sensor). P2 means a 12 – 48 Vdc supply.
Shunts of 50 A to 4000 A at 75 mV and Hall sensors HAK21, HAK40 and HAB-16555 are listed as additional sensors, sold separately; the sensor code adds an A2 or A3 output and a B suffix for bi-directional versions.
Wiring and commissioning notes
Wiring diagrams show voltage and current wiring using shunts or Hall sensors on both channels. The unit needs a separate 12 – 48 Vdc supply, and the sensor must match the A1, A2 or A3 code the meter was ordered with.
Configure cable resistance for loss compensation only after measuring the real cable run, and keep the metrology seal and cover seal in place after calibration checks.
Applications
The datasheet names DC fast EV charging stations, data centres, renewable generation and storage, solar PV, wind, DC energy management, DC grids, light rail systems and cellular towers. General engineering note: a dual-channel unit lowers cost per charging gun on twin-outlet chargers.
Related Accuenergy items
The AcuDC 243 is the general-purpose DC meter; the AcuDC-301 is the single-outlet EV transaction meter. Browse the power meters category.
Commissioning and enquiry notes
DC metering is increasingly needed in the region as EV charging networks, solar PV plants and battery storage systems grow. A dual-channel meter suits chargers with two outlets and DC distribution panels where two feeders must be measured from one shared voltage point. Select the current sensors for the expected range of each channel and follow the wiring and grounding instructions in the manual carefully.
Chargers and outdoor cabinets can become very hot in summer, so check the internal temperature of the cabinet against the meter rating. Where readings are used for billing, confirm with the local authority and the charging network operator which approvals and data formats are required.
Record the channel assignments and sensor settings at commissioning, so later maintenance and billing checks can be traced to the right outlet.
Information to send with an enquiry
- System voltage and current range per channel
- Sensor type for each channel
- Communication: RS485, Ethernet or both
- Quantity
Frequently asked questions
What accuracy does AcuDC-262 offer?
0.1 percent on voltage from 12 V to 1000 V, 0.2 percent on current and 0.5 percent on power, energy and charge under IEC 62053-41 class 0.5.
How many channels does it measure?
One DC voltage input and two DC current inputs, with per-channel and summed energy and charge.
Which communication ports are provided?
Modbus RTU over RS485 and Modbus TCP/IP over a 10/100 Mbps Ethernet port.
How long can it log data?
Three data loggers plus a trend logger store one-minute records for up to 16 months in 16 MB memory.
Does Seven Star LLC act as an Accuenergy distributor?
No. Seven Star LLC is not an Accuenergy distributor; it is an independent Muscat-based supplier that quotes Accuenergy products on request.
Documents and quotation
The official Accuenergy datasheet and user manual for AcuDC-262 are hosted on this page for download. Seven Star LLC is an independent supplier in Muscat; send your quantity and delivery location through the quotation form and we will quote this item. Please confirm the exact order code, supply voltage and output options against the documents before ordering. More related products: product category.
Datasheets & Documents
- Datasheet Accuenergy AcuDC-262 Advanced DC Power and Energy Meter datasheet, version 1.0.2 (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Accuenergy is a power and energy metering company founded in 1998 and headquartered in Toronto, Canada, with offices in El Segundo (United States), Xi'an (China) and Pretoria (South Africa). Its website reports more than one million instruments delivered and meters deployed in over 170 countries.
Power meters, DC meters and submeters
The Accuenergy range covers Acuvim multifunction and power quality meters, AcuRev DIN rail meters and multi-circuit submeters, AcuDC meters for DC systems and EV charging, plus current transformers, Rogowski coils and communication modules. Each datasheet lists accuracy classes, inputs, communication options and ordering codes. Accuenergy states that its operations hold ISO 9001, ISO 14001 and ISO 45001 certification and that its management systems are certified to ISO 27001 and ISO 50001.
Supply through Seven Star LLC
Seven Star LLC is an independent supplier in Muscat that quotes Accuenergy products for projects in Oman and the GCC, with the official Accuenergy datasheet attached to each product page.
Related products
Frequently Asked Questions
0.1 percent on voltage from 12 V to 1000 V, 0.2 percent on current and 0.5 percent on power, energy and charge under IEC 62053-41 class 0.5.
One DC voltage input and two DC current inputs, with per-channel and summed energy and charge.
Modbus RTU over RS485 and Modbus TCP/IP over a 10/100 Mbps Ethernet port.
Three data loggers plus a trend logger store one-minute records for up to 16 months in 16 MB memory.
No. Seven Star LLC is not an Accuenergy distributor; it is an independent Muscat-based supplier that quotes Accuenergy products on request.