Brand: Leybold
Leybold 960 345 SOGEVAC SV 40 ATEX Cat 2 Vacuum Pump IIB+H2
Description
An explosion-protected SOGEVAC for Zone 1 and Zone 2 vacuum lines
The Leybold 960 345 is the SOGEVAC SV 40 ATEX LA IIB+H2 with permanent gas ballast, for the 50 Hz supply. It is an ATEX Category 2 version of the SV 40 B oil-sealed rotary vane pump, marked II 1/2 G Ex h IIB+H2 T4 Ga/Gb for an ambient range of +5 to +40 degrees C and documented under EC Type Examination Certificate PTB 04 ATEX 4013 Issue 1 in accordance with Directive 2014/34/EU, as printed in the catalogue.
The marking 1/2 means the pump is rated Category 1 inside and Category 2 outside, so it may be connected to a process where the gas inside the pump can be flammable. The designation IIB+H2 indicates the gas group: hydrogen and gases of group IIB are covered, while the IIA versions of the same pump (960 342 and 960 344) are limited to group IIA. Hazard analysis remains the operator duty; the catalogue states that the customer must perform it as soon as gases capable of exploding are pumped or are present nearby.
Technical data of the SV 40 ATEX
| Parameter | Specification |
|---|---|
| Part number / type | 960 345 / SOGEVAC SV 40 ATEX LA IIB+H2, permanent gas ballast, 50 Hz |
| Marking and certificate | II 1/2 G Ex h IIB+H2 T4 Ga/Gb (+5 degrees C below Ta below 40 degrees C); EC Type Examination Certificate PTB 04 ATEX 4013 Issue 1 |
| Nominal pumping speed | 46.0 m3/h (27.1 cfm) at 50 Hz; 55.2 m3/h (32.5 cfm) at 60 Hz |
| Pumping speed per PNEUROP | IIB+H2: 26 m3/h (15.3 cfm) at 50 Hz, 29 m3/h (17.1 cfm) at 60 Hz; IIA: 35 m3/h (20.6 cfm) and 42 m3/h (24.7 cfm) |
| Ultimate total pressure | 0.8 mbar (0.6 Torr) without gas ballast; 1.5 mbar (1.1 Torr) with gas ballast |
| Water vapour tolerable load | 30 mbar (23 Torr) with gas ballast |
| Noise level (DIN 45635) | 63 dB(A) at 50 Hz; 68 dB(A) at 60 Hz |
| Motor | 1.5 kW (2.0 hp) at 1500 rpm on 50 Hz; 1.8 kW (2.4 hp) at 1800 rpm on 60 Hz; standard voltage 230/400 V +/-10 % and 460 V +/-10 % |
| Protection class | IP 55-F |
| Oil | LEYBONOL LVO 210, approx. 2 l (2.1 qt) |
| Leak rate | 1 x 10-3 mbar l/s or less |
| Weight with oil | 110 kg (243 lbs) |
| Connections | Intake G 1 1/4 inch for IIB+H2 (G 3/4 inch for IIA); exhaust G 1 1/4 inch; DN 16 ISO-KF gas ballast connection supplied |
| Maximum gas inlet temperature | 40 degrees C (104 degrees F) |
| Materials in contact with gas | Steel, cast iron, aluminium, bronze, FPM (FKM), glass, polyamide 6.6, filter material, epoxy resin and glass fibre |
ATEX variants in the SV 40 ATEX ordering table
| Part No. | Supply | Gas group / marking as printed | Gas ballast |
|---|---|---|---|
| 960 345 | 50 Hz | IIB+H2, T4 | Permanent |
| 960 349 V 3060 | 60 Hz | IIB+H2, printed with 160C | Permanent |
| 960 346 | 50 Hz | IIB+H2, T4 | None |
| 960 343 | 50 Hz | IIB+H2, T4 | With MR40 B pressure regulator |
| 960 344 | 50 Hz | IIA, T3 (PTB 04 ATEX 4011 Issue 1) | None |
| 960 342 | 50 Hz | IIA, T3 (PTB 04 ATEX 4011 Issue 1) | With MR40 B pressure regulator |
Accessories and spare parts for these pumps are given as upon request, and the catalogue asks that all enquiries and orders for category 1 and 2 ATEX products use the ATEX questionnaire printed at the end of the full-line catalogue.
Built-in protection and what is delivered
- Standard equipment includes FPM (FKM) seals, an oil filter bypass and LEYBONOL LVO 210 oil, with special ATEX exhaust filters, couplings, motors and floats.
- All pumps carry Pt100 temperature, oil level and oil casing pressure sensors, and the motors have PTC thermistors for monitoring.
- The pump is supplied with special Operating Instructions (GA), a Spare Parts List (ET) and a CE declaration, which must be observed.
- Only special accessories (filters, valves, taps) and original Leybold spare parts may be used, and restrictions apply to service and repairs: contact Leybold before attempting them.
Selecting and installing in a hazardous area
Choose 960 345 when the process gas contains hydrogen or group IIB vapours and the plant runs on 50 Hz, which covers the GCC electricity grids. Gas groups, temperature class and zone must be matched to the hazardous area classification of the installation by the responsible engineer; the catalogue states pumping speed curves are the same as for non-ATEX SOGEVAC pumps, so sizing can follow the standard SV 40 B curves. Operation is possible at all pressures between 1000 mbar and ultimate pressure, and the pump can be air or water cooled.
Typical uses in oil, gas and chemical plants
ATEX pumps of this type are used where a vacuum source sits in or beside a classified area: solvent recovery, vapour extraction from tanks, vacuum filling of chemical containers, laboratory and pilot plants in petrochemical sites. Keep the gas inlet temperature below 40 degrees C and avoid acetylene or other gases outside the declared gas group.
Send the gas group, zone and supply frequency with your enquiry and we will check them against the table above. More equipment sits in the pumps category.
Selection and installation notes
A vacuum pump is selected from the pumping speed, the ultimate pressure and the gases or vapours it will handle. Use the oil grade the maker names, check the oil level before starting, connect the exhaust to a safe place and fit an oil mist filter where needed, use a trap or filter ahead of the pump for dust and vapour and warm the pump before pumping condensable vapour. Service the oil and filters on the schedule in the manual.
For a hazardous area, use only the certified version, keep the ATEX marking and the supply and gas conditions within the certificate and follow the local hazardous area rules.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Frequently asked questions
What is Leybold 960 345?
It is the SOGEVAC SV 40 ATEX LA IIB+H2 vacuum pump with permanent gas ballast for 50 Hz, an ATEX Category 2 version of the SV 40 B.
What explosion marking is printed?
II 1/2 G Ex h IIB+H2 T4 Ga/Gb for +5 to +40 degrees C, with EC Type Examination Certificate PTB 04 ATEX 4013 Issue 1 per the catalogue.
Which oil does it use?
LEYBONOL LVO 210, about 2 l, with FPM (FKM) seals and an oil filter bypass as standard.
Does it have monitoring sensors?
Yes. The catalogue states Pt100 temperature, oil level and oil casing pressure sensors, plus PTC thermistors in the motor.
Does Seven Star LLC certify the ATEX marking?
No. The marking is Leybold’s, as printed in its catalogue. Seven Star LLC is an independent supplier in Muscat and asks you to confirm gas group and zone suitability.
Datasheets & Documents
- Datasheet Leybold Full Line Catalog 2022, oil sealed vacuum pumps: SOGEVAC SV 40 ATEX extract (catalogue pages 98-99 and 134-137) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Leybold is a German vacuum technology company, founded in Cologne in 1850 by Ernst Leybold and part of the Atlas Copco Group since 2016. Its catalogue covers rotary vane, screw, dry and turbomolecular vacuum pumps, vacuum systems, gauges and components for industrial and research processes.
Seven Star LLC is an independent supplier in Muscat. We list selected Leybold pumps with the official catalogue pages for industrial and laboratory users in Oman and the GCC.
Leybold product series
SOGEVAC single-stage oil-sealed rotary vane pumps on this site include the SV 16 D, SV 25 B, SV 100 B and SV 220 B, and the SV 40 ATEX Category 2 pump for gas group IIB+H2. Two-stage rotary vane pumps include the NEO D 25 and the TRIVAC D 40 B, and the TRIVAC D 16 B-Ex is an explosion-protected version.
The VACUBE VQ 400 i and VQ 700 i are oil-sealed screw vacuum pumps with variable speed drive for larger volume flows. The catalogue numbers (for example 960 250) identify the exact pump variant and motor.
Where Leybold pumps are used
Vacuum packaging and food processing, drying and degassing, coating, metallurgy and heat treatment, transformer and power engineering work, chemical processes, laboratories and analytical instruments. ATEX versions serve areas where explosive gases may be pumped.
Ordering Leybold pumps: what we need
Send the Leybold catalogue number from the nameplate, or the pumping speed, ultimate pressure, gas or vapour being pumped, motor voltage and frequency, and any ATEX requirement. For service, state the pump model and serial number so the right oil, filters and kits can be quoted.
Browse Leybold products by category: Pumps.
Related products
Frequently Asked Questions
It is the SOGEVAC SV 40 ATEX LA IIB+H2 vacuum pump with permanent gas ballast for 50 Hz, an ATEX Category 2 version of the SV 40 B.
II 1/2 G Ex h IIB+H2 T4 Ga/Gb for +5 to +40 degrees C, with EC Type Examination Certificate PTB 04 ATEX 4013 Issue 1 per the catalogue.
LEYBONOL LVO 210, about 2 l, with FPM (FKM) seals and an oil filter bypass as standard.
Yes. The catalogue states Pt100 temperature, oil level and oil casing pressure sensors, plus PTC thermistors in the motor.
No. The marking is Leybold's, as printed in its catalogue. Seven Star LLC is an independent supplier in Muscat and asks you to confirm gas group and zone suitability.

Reviews