Brand: TDK Electronics (EPCOS)
TDK B84771A0010A000 10 A IEC Inlet EMC Filter, 250 V AC
Description
A 10 A mains inlet that filters noise at the appliance entry
The TDK B84771A0010A000 combines a standard IEC 60320 appliance inlet with a two-line EMC filter. The mains cable plugs into the C14 inlet on the line side and the load side leaves through tab connectors, so the filter sits right at the equipment entry and keeps conducted noise from switch-mode power supplies out of the mains. It is rated 10 A at 50 C on 250 V AC, 50/60 Hz, and the A in the code means the version with a discharge resistor.
The same series also offers C types without discharge resistor and M types for medical equipment with negligible leakage current.
Datasheet values for the 10 A inlet filter
| Parameter | Specification |
|---|---|
| Ordering code | B84771A0010A000 |
| Series | B84771 IEC inlet filters, power line filters for 1-phase systems |
| Version | A: with discharge resistor (C: without; M: medical, negligible leakage) |
| Rated voltage VR | 250 V AC, 50/60 Hz (series also 250 V DC) |
| Rated current IR | 10 A, referred to 50 C rated temperature |
| X2 capacitor CX | 1 x 0.1 uF |
| Y2 capacitors CY | 2 x 2200 pF |
| Inductance LR | 2 x 0.24 mH |
| Leakage current ILK | 0.173 mA (calculated to IEC 60939-1 annex A at rated voltage and 50 Hz; up to double in practice) |
| Discharge resistor Rdis | 1 MOhm |
| Weight | Approx. 40 g |
| Line-side connection | IEC connector C14 according to IEC 60320-1 |
| Load-side connection | Tab connectors 6.3 x 0.8 mm, screw-mounting version |
| Degree of protection | IP40 at the front side with power plug |
| Test voltage | 1000 V AC for 2 s line to line (1 A to 15 A types); 2000 V AC for 2 s lines to case |
| Climatic category (IEC 60068-1) | 25/085/21 |
| Approvals and standards | EN 60939, UL 1283, CSA C22.2 No.8; ENEC, UL and cUL approval (ENEC for the 12 A and 15 A types is at 10 A) |
| Construction | Metal case, compact, cost optimised |
Versions and ratings in the B84771 series
The datasheet covers 1 A to 20 A. Up to 15 A the inlet is C14; the 16 A and 20 A types use a C20 connector, a larger X2 capacitor of 0.33 uF and a weight of 130 g. The ENEC approval of the 12 A and 15 A types applies at 10 A, and for the 20 A type at 16 A. Litz-wire load-side versions with 18 AWG or 16 AWG leads are listed separately in the datasheet.
- Choose the A type when a discharge resistor across the line is wanted; C omits it.
- Choose M types for medical equipment where leakage current must be minimal.
- Pick current at 50 C ambient; the 10 A rating is referred to 50 C, not 40 C as on panel-type filters.
Reading the datasheet values
Two things define the electrical behaviour of this code: the 2 x 0.24 mH inductors in the live and return paths, and the capacitor set of one 0.1 uF X2 capacitor with two 2200 pF Y2 capacitors to earth. The low leakage figure of 0.173 mA is calculated according to IEC 60939-1 annex A; TDK states that, because of the insulation resistance of the ceramic capacitors, up to double that value can be expected in practice. The 1 MOhm resistor of the A version discharges the X capacitor after the plug is pulled.
Mounting and safety
The screw-mounting version bolts into a panel cut-out, so the inlet face is visible and accessible. TDK warns that qualified persons must carry out installation, that the filter stores charge, that the protective earth must be connected first, and that the component can become very hot in operation. Because mechanical loads must not be taken by the filter, the cable plug should not be used as a strain relief point for heavy cords. Where the equipment is to be used in a medical setting, the M version rather than this A version is the one designed for negligible leakage.
Where it is used
Typical applications in the datasheet are switch-mode power supplies, industrial electronics, telecom and data systems, measuring instruments and medical equipment. In a GCC context that points to analyser cabinets, instrumentation power supplies, telecom shelters and control-room equipment, where each unit is plugged into a 230 V supply. For larger panel filters see the electrical and power category.
Selection and installation notes
An EMC filter or reactor is selected from the rated current at the actual ambient temperature, the supply voltage and the drive or load it serves. Fit it as close as possible to the drive input, keep the cable between filter and drive short, bond the housing to the panel back plate with a clean metal contact, separate input and output cables, and check the leakage current against the protective earth requirements of the installation.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Frequently asked questions
What does the A in B84771A0010A000 mean?
It denotes the version with a discharge resistor; C is without and M is the medical version with very low leakage current.
What is the rated current and temperature?
10 A, referred to 50 C rated temperature, at 250 V AC and 50/60 Hz.
How does it connect?
The line side is an IEC C14 appliance inlet; the load side uses 6.3 x 0.8 mm tab connectors in the screw-mounting version.
What protection degree does it have?
IP40 at the front side with the power plug fitted, according to IEC 60529.
Who supplies this part in Oman?
Seven Star LLC is an independent supplier in Muscat and not the manufacturer. Confirm the version (A, C or M) and mounting style before ordering.
Datasheets & Documents
- Datasheet TDK B84771 IEC inlet filters datasheet (November 2023) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
TDK Electronics, which still markets many components under the EPCOS name, is the electronic components and power quality business of TDK Corporation, the Tokyo-based group established in 1935.
Seven Star LLC is an independent supplier in Muscat. We list selected TDK Electronics (EPCOS) items with the official data sheet attached to every product page, for panel builders and power quality projects in Oman and the GCC.
TDK Electronics product series
Power factor correction components include the DeltaCap X Black 25 kvar 440 V capacitor, the B44066 capacitor contactor for switching capacitor steps and the FilterCap gas-filled AC capacitor for inverter filters.
Drive and EMC components include three-line EMC filters such as the 600 A B84143B0600S080 for converters, the 50 A four-line filter with neutral, the 40 A single-phase filter and the 10 A IEC inlet filter, as well as three-phase line reactors, the 180 A dv/dt output reactor that protects motor insulation and the 66 A LCL filter for active infeed converters.
Where TDK Electronics components are used
Capacitor banks and detuned filter panels, frequency converter and drive cabinets, UPS and inverter systems, and electronic equipment that must meet EMC limits.
Ordering TDK Electronics components: what we need
Send the ordering code starting with B, such as B32305A4252B040, together with the quantity. If the code is not known, give the voltage, rated power in kvar or rated current, number of lines, mounting and the drive or system the part is used with.
Browse TDK Electronics (EPCOS) products by category: Power Modules, Contactors & Overload Relays.
Related products
Frequently Asked Questions
It denotes the version with a discharge resistor; C is without and M is the medical version with very low leakage current.
10 A, referred to 50 C rated temperature, at 250 V AC and 50/60 Hz.
The line side is an IEC C14 appliance inlet; the load side uses 6.3 x 0.8 mm tab connectors in the screw-mounting version.
IP40 at the front side with the power plug fitted, according to IEC 60529.
Seven Star LLC is an independent supplier in Muscat and not the manufacturer. Confirm the version (A, C or M) and mounting style before ordering.

Reviews