Brand: ABB
ABB ACQ580-01-018A-4 Water Drive 7.5 kW 17 A
Description
7.5 kW pump drive on frame R2
Municipal and industrial pump stations that need a 7.5 kW drive for a 380 to 480 V supply can use the ACQ580-01-018A-4. It delivers 17 A nominal from a frame R2 housing and combines an EMC filter, a DC choke, Safe Torque Off and Modbus RTU in the basic unit. It opens frame R2 at 7.5 kW and fits mid-size transfer and booster sets.
Typical functions in the ACQ580 pump control program are resonance monitoring, real-time clock scheduling, soft pipe filling to avoid pressure peaks and quick ramps that reduce wear on submersible pumps. Other ratings sit in AC drives, with the series description on the ABB ACQ580 page.
Technical specifications
| Parameter | Specification |
|---|---|
| Type code | ACQ580-01-018A-4 |
| Platform | ACQ580-01 wall-mounted pump drive |
| Input supply | Code 4: 380-480 V, three-phase |
| Housing frame | R2 |
| Nominal use | 7.5 kW, 17 A |
| Light-duty output | 7.5 kW, 16.2 A |
| Heavy-duty output | 5.5 kW, 12.6 A |
| Imax | 22.7 A (2 s at start) |
| Input protection | IEC 40 A 170M1563; UL 30 A JJS-30 |
| Thermal data | 240 W; 101 m3/h; max. 64 dBA |
| Enclosure options | IP21 standard; +B056 gives IP55 |
| Size in IP21 | 473 x 125 x 229 mm, 6.6 kg |
| Size and weight in IP55 | 503 x 128 x 239 mm, 6.8 kg |
Light and heavy duty on 17 A
Pick the duty by load: 16.2 A / 7.5 kW suits centrifugal pumps, with 110% for 60 seconds (about 17.8 A, derived). Positive-displacement or sludge pumps with high breakaway torque may need the heavy-duty column, 12.6 A / 5.5 kW, which permits 150% for a minute (about 18.9 A, derived). The 2-second start limit is 22.7 A, and nominal use is 17 A.
Input fuses are 40 A type 170M1563 to IEC and 30 A type JJS-30 to UL. The drive dissipates about 240 W, moves 101 m3/h of air and is rated at no more than 64 dBA at full fan speed; detailed fuse sizes are in the hardware manual 3AXD50000044862.
Dimensions for frame R2: IP21 473 x 125 x 229 mm at 6.6 kg; IP55 503 x 128 x 239 mm at 6.8 kg (heights include the gland box). With a main switch or C1 filter fitted, ABB lists the IP55 body at 503 x 128 x 257 mm and 7.5 kg.
Motor pairing: the catalogue’s SynRM selection guide matches this drive with 7.5 kW M3AL132SMB4 at 3000 rpm (16.5 A nominal, motor efficiency 93.1%, package efficiency 90.4%); 7.5 kW M3AL132SMB4 at 1500 rpm (15.7 A nominal, motor efficiency 93.7%, package efficiency 91%); 7.5 kW M3BL160MLA4 at 1000 rpm (16.5 A nominal, motor efficiency 93.1%, package efficiency 90.2%). Efficiency numbers describe that combination only and are calculated by ABB.
Type code and option codes
ACQ580-01-018A-4 breaks down as ACQ580 (series), 01 (wall-mounted), 018A (rating) and 4 (380 to 480 V). The standard panel is the Hand-Off-Auto ACH-AP-H. Typical extras are +L501 for CMOD-01 (24 V and relay), +L512 for CHDI-01 (115/230 V inputs), +L523 for CMOD-02 (isolated PTC) and +L525 for CAIO-01 (3 AI, 2 AO).
Communication: Modbus RTU is built in. For plant networks, ABB’s table gives PROFIBUS DP FPBA-01 (+K454, 68469325), CANopen FCAN-01 (+K457, 68469376) and Modbus RTU FSCA-01 (+K458, 3AUA0000031336). The fieldbus module sits in slot one and I/O extensions in slot two.
Across the family the catalogue specifies Safe Torque Off to SIL 3 / PL e, EMC class C2 as standard for ACQ580-01, a C1 option up to 55 kW, a built-in DC or AC choke meeting IEC 61000-3-12 and 6 digital inputs, 2 analog inputs, 2 analog outputs and 3 relays.
Documentation and quotation
Values come from ABB’s drives for water and wastewater ACQ580 catalogue (3AUA0000194172, revision I, 27.9.2024), linked on this page. Seven Star LLC supplies the ACQ580-01-018A-4 on request from Muscat; send the pump motor nameplate, supply voltage, enclosure class and fieldbus with your RFQ, and the quotation states availability and lead time.
Confirm before ordering: the full type code with plus options, motor current at your voltage, ambient temperature and altitude, and any ATEX or corrosion requirement.
Datasheets & Documents
- acq580cat Catalog Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.
Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.
ABB product families on this page
Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.
Where ABB instruments and drives are used
Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.
Ordering ABB parts: what we need
For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.
Related products
Frequently Asked Questions
ABB lists 17 A nominal for 7.5 kW, 16.2 A light duty for 7.5 kW and 12.6 A heavy duty for 5.5 kW, with a maximum output current of 22.7 A.
The catalogue lists 40 A IEC fuses of type 170M1563 and 30 A UL fuses of type JJS-30.
The catalogue gives a typical heat dissipation of 240 W, cooling air of 101 m3/h and a maximum noise level of 64 dBA at full fan speed.
Frame R2 measures 473 x 125 x 229 mm in IP21 at 6.6 kg and 503 x 128 x 239 mm in IP55 at 6.8 kg, with the gland box included in the height.
Add +B056 to the type designation. ABB lists it as the IP55 / UL Type 12 unit for frames R1 to R9.