- Industrial Communications
- AC Drives
- Vibration Monitoring
- PLC & I/O Cards
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Encoders
- Industrial Computers
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Servo Drives
- Automation Software
- Robotics
- Machine Vision
Brand: MOXA
Moxa EDS-G512E-4GSFP 12-Port Full Gigabit Managed Switch
Description
What the EDS-G512E-4GSFP does on the plant network
Twelve Gigabit ports, of which four are SFP slots, in a managed DIN-rail switch designed for high-bandwidth industrial rings and aggregation points. Moxa’s own one-line description of the EDS-G512E-4GSFP reads: 12-port full Gigabit managed Ethernet switch with 8 10/100/1000BaseT(X) ports, 4 Gigabit SFP slots, -10 to 60°C operating temperature.
From the manufacturer’s specification table, the power input is 12/24/48/-48 VDC; operating temperature is -10 to 60°C (14 to 140°F); dimensions are 79.2 x 135 x 137 mm (3.1 x 5.3 x 5.4 in); weight is 1,440 g (3.18 lb); the enclosure is rated IP30.
Standards and approvals printed for this model include hazardous-location listings of Class I Division 2; ATEX; marine approvals (LR; ABS; DNV; NK); railway standard EN 50121-4; safety standard UL 508. Approvals can differ between variants of a series, so check the one on the exact order code.
Technical specifications
| Parameter | Specification |
|---|---|
| Alarm Contact Channels | 1; Relay output with current carrying capacity of 1 A @ 24 VDC |
| Buttons | Reset button |
| Digital Input Channels | 1 |
| Digital Inputs | +13 to +30 V for state 1; -30 to +3 V for state 0; Max. input current: 8 mA |
| 10/100/1000BaseT(X) Ports (RJ45 connector) | 8; Auto negotiation speed; Full/Half duplex mode; Auto MDI/MDI-X connection |
| 100/1000BaseSFP Slots | 4 |
| Industrial Protocols | EtherNet/IP; Modbus TCP; PROFINET IO Device |
| Redundancy Protocols | Link Aggregation; MRP; MSTP; RSTP; STP; Turbo Chain; Turbo Ring v1/v2 |
| Time Management | NTP Server/Client; SNTP |
| IGMP Groups | 2048 |
| Jumbo Frame Size | 9.6 KB |
| MAC Table Size | 8 K |
| Max. No. of VLANs | 256 |
| Packet Buffer Size | 4 Mbits |
| Priority Queues | 4 |
| VLAN ID Range | VID 1 to 4094 |
| Storage Port | USB Type A |
| Console Port | USB-serial console (Type B connector) |
| DIP Switches | Turbo Ring, Master, Coupler, Reserve |
| Connection | 2 removable 4-contact terminal block(s) |
| Input Current | 0.44 A @ 24 VDC |
| Input Voltage | 12/24/48/-48 VDC |
| Operating Voltage | 9.6 to 60 VDC |
| Overload Current Protection | Supported |
| Reverse Polarity Protection | Supported |
| Housing | Metal |
| IP Rating | IP30 |
| Dimensions | 79.2 x 135 x 137 mm (3.1 x 5.3 x 5.4 in) |
| Weight | 1,440 g (3.18 lb) |
| Installation | DIN-rail mounting; Wall mounting (with optional kit) |
| Operating Temperature | -10 to 60°C (14 to 140°F) |
| Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Safety | UL 508 |
| EMI | FCC Part 15B Class A |
| Hazardous Locations | Class I Division 2; ATEX |
| Power Substation | IEC 61850-3; IEEE 1613 |
| Railway | EN 50121-4 |
| Traffic Control | NEMA TS2 |
| Vibration | IEC 60068-2-6 |
| Shock | IEC 60068-2-27 |
| Freefall | IEC 60068-2-32 |
| Maritime | LR; ABS; DNV; NK |
| Warranty Period | 5 years |
Selection and installation notes
The series also offers PoE+ models with eight PoE ports for camera and access-point installations, so one platform covers both network core and edge needs.
On the practical side, mounting is listed as din-rail mounting; wall mounting (with optional kit); the housing is metal; the stated MTBF is 803,337 hrs; the warranty period is 5 years. Treat the MTBF as a manufacturer prediction under its stated method, not a guarantee for your site.
Please check the SFP modules, the PoE or non-PoE version in the series, and the supply voltage before you place an order. Seven Star LLC supplies as an independent company and prices against the precise code requested.
Related models in the EDS-G512E-4GSFP family
The Moxa product list shows these models in the same family page (4 entries): EDS-G512E-4GSFP, EDS-G512E-4GSFP-T, EDS-G512E-8POE-4GSFP, EDS-G512E-8POE-4GSFP-T. Suffixes such as -T generally mark wide-temperature versions and fiber suffixes (M, S, MM, SS with SC or ST) mark the connector and fiber type, but the order code printed on the datasheet governs.
Planning the network around this switch
Decide early whether the EDS-G512E-4GSFP will sit in a ring, act as a coupler between rings, or aggregate several edge switches. The redundancy protocol chosen, whether Turbo Ring, MRP or RSTP, must be supported by every device in the same ring, so list the neighbouring switches and controllers before fixing the design. For PROFINET or EtherNet/IP networks, confirm with the automation engineer which protocol features the control system will actually use.
Count copper and fibre links separately. The four SFP slots suit uplinks that run between buildings, along conveyors or across a substation yard, but each slot needs a transceiver that matches the fibre type, distance and speed at both ends of the link. Confirm SFP module compatibility with the switch documentation before ordering, and size the power supply for the input current of the switch with margin for any other loads on the same DC circuit.
Installation in the control panel
Mount the switch on the DIN rail in a location with free air around the metal housing, away from drives, contactors and other heat sources. Keep data cables apart from power wiring, use shielded cable where the plant standard requires it, and support fibre patch leads so they are not bent tightly at the panel door. Wire the relay alarm output and the digital input to the control system if supply failure or link loss should raise an alarm in the SCADA.
Commissioning and configuration
Before connecting the switch to a live network, give it a unique IP address and set site-specific access credentials in line with the plant security policy. Configure VLANs, port settings, redundancy roles and time synchronisation, then test ring recovery by disconnecting one link under controlled conditions and confirming that traffic continues. Export the final configuration and store it with the panel drawings so a replacement unit can be set up quickly. Disable unused ports and services as part of basic cybersecurity hygiene.
Operating conditions in Oman and the GCC
The standard model is rated for -10 to 60 °C, and panels in outdoor kiosks, pipeline stations or rooftop plant rooms in Oman can approach that upper limit in summer when sun load is added to equipment heat. Shade, ventilation or cooling for the enclosure helps keep the switch within its rating. Because the housing is IP30 and humidity must be non-condensing, the panel itself has to keep out dust and moisture, especially at coastal sites. During maintenance, check panel filters, inspect fibre connectors for contamination, review logged alarms for repeated link losses, and apply firmware updates through a controlled change procedure.
Documents and quotation
The attached file is Moxa’s published datasheet for the family (moxa-eds-g512e-series-datasheet-v2.1). For a quotation, send the full order code, the quantity required and where the goods are to be delivered.
More products in this range: Industrial Communications.
Datasheets & Documents
- Datasheet Moxa EDS-G512E series datasheet v2.1 Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Since 1987 Moxa, based in New Taipei City, Taiwan, has built networking hardware for places where an office switch would fail: substations, wellhead panels, roadside cabinets. Seven Star LLC lists Moxa industrial Ethernet switches and fiber converters and supplies Moxa networking devices to system integrators and plant teams in Oman as an independent supplier. Each request is checked against the full Moxa model name before we quote.
Moxa switches and converters listed here
The EDS-G508E is a managed switch with eight Gigabit ports from the EDS managed line. The EDS-316-MM-SC-T is a 16-port unmanaged switch with 14 copper ports, two multi-mode SC fiber ports and the wide-temperature option (-40 to 75 C). The TCF-142-S-SC-T belongs to the TCF-142 series, which converts RS-232/422/485 serial signals to single-mode fiber. Moxa also makes serial device servers, protocol gateways, wireless devices and industrial computers, used on SCADA and telemetry networks across the GCC.
Ordering Moxa devices: what we need
The suffixes carry the specification. Send the complete model name, including fiber mode and connector (MM-SC, SS-SC, ST), the -T wide-temperature suffix and any coating or approval suffix. Add the power supply voltage, the SFP modules needed and the quantity.
Browse MOXA products by category: Industrial Communications.
Related products
Frequently Asked Questions
Moxa lists it as: 12-port full Gigabit managed Ethernet switch with 8 10/100/1000BaseT(X) ports, 4 Gigabit SFP slots, -10 to 60°C operating temperature. Twelve Gigabit ports, of which four are SFP slots, in a managed DIN-rail switch designed for high-bandwidth industrial rings and aggregation points.
The Moxa specification gives an input voltage of 12/24/48/-48 VDC. Check the terminal arrangement and, where relevant, the redundant-input wiring against your panel supply before ordering.
The listed operating temperature is -10 to 60°C (14 to 140°F). Wide-temperature versions carry a -T suffix in Moxa's order codes where the series offers them, and they are separate order codes.
It is a managed switch, so VLANs, redundancy and security are set through its web, console or SNMP interfaces.
The official Moxa datasheet is attached to this page. Send Seven Star LLC the exact order code, quantity and delivery location for a quotation; we are an independent supplier in Muscat.

Reviews