ABB ACS580-01-073A-4 AC Drive 37 kW 73 A

Description

A 37 kW ACS580-01 for 400 V motors

At 37 kW this rating is typical for substantial pump stations and fan banks, and the heat loss rises to 858 W so cabinet or room cooling needs checking. The matching ABB part is the ACS580-01-073A-4, a 3-phase drive for 380 to 480 V with 73 A nominal output current and 37 kW typical motor power, packed into a frame R4 body that stands 203 mm wide.

ABB aims the ACS580-01 at light industry such as food and beverage, plastics, textiles, material handling and agriculture. A DC/AC choke, EMC filter, Modbus RTU port and STO function come as standard, so a panel builder needs little extra hardware. Browse more in AC drives or read the ABB ACS580 series page.

Technical specifications

Parameter Specification
Type designation ACS580-01-073A-4
Series / construction ACS580 / 01 = wall-mounted
Supply voltage 3-phase, 380 to 480 V (code 4)
Frame size R4
Nominal rating (no overload) 37 kW, 73 A at 400 V
Light-duty use at 400 V 68.4 A, 37 kW (110% for 1 min every 10 min)
Heavy-duty use at 400 V 61 A, 30 kW (150% for 1 min every 10 min)
Maximum output current 109.8 A for 2 s at start
Ratings at 480 V Light duty 65 A / 50 hp, heavy duty 52 A / 40 hp, maximum 104 A
Recommended input fuse IEC 100 A gG; UL 90 A Class T
Typical heat dissipation 858 W
Cooling air flow 150 m3/h (88 ft3/min), max. noise 70 dBA
Maximum recommended motor cable 300 m
Dimensions, IP21 standard 636 mm with glandbox x 203 x 257 mm
Weight, IP21 standard 19 kg
Standard enclosure IP21 / UL Type 1

Sizing the ACS580-01-073A-4 for your motor

Overload data decide whether ACS580-01-073A-4 is the right size. In light-duty use the catalogue allows 68.4 A continuously and 110% of that, about 75.2 A, for one minute in ten at 40 degrees C. In heavy-duty use the continuous figure drops to 61 A, which allows 150%, about 91.5 A, for the same minute. Select by motor nominal current, not only by kilowatts.

Cabinet designers should allow 858 W and 150 m3/h of air flow. Maximum recommended motor cable is 300 m, and the catalogue fuse is 100 A gG (90 A UL Class T). If the load turns out to be 30 kW or less, ACS580-01-062A-4 may fit (62 A); above 45 kW the next type is ACS580-01-089A-4 at 89 A.

Ordering code and enclosure options

Decode the code as follows: ACS580 is the product series, 01 the wall-mounted construction, 073A the rating designation from the catalogue table, and 4 the 380 to 480 V voltage range. Option codes follow with a plus sign: +B056 (IP55 / UL Type 12, R1 to R9), +B063 (IP66 / UL Type 4X), +F278 (integrated main switch, R1 to R5), +E223 (integrated C1 filter, R1 to R5), +C135 (flange mounting) and +P944 (conduit box removal, R5 to R9).

The IP55 version of this frame measures 636 (879 with options) x 203 x 265 mm. The catalogue dimension table lists IP66 only for frames R1 to R3. Fieldbus options include PROFIBUS DP (+K454, FPBA-01), Modbus RTU (+K458, FSCA-01), Two-port EtherNet/IP (+K490, FEIP-21) and Two-port Modbus/TCP (+K491, FMBT-21). Order the exact type code shown above and add options only where the project needs them.

Built-in features that reduce panel hardware

Several items that are often bought separately for a drive of this size are already inside the ACS580-01-073A-4:

  • DC/AC choke: reduces input current harmonics, which helps where several drives share one transformer or a generator.
  • EMC filter: limits conducted emissions back into the supply network.
  • Safe Torque Off (STO): a hardware input that removes torque from the motor, used as part of a machine safety function designed by the integrator.
  • Modbus RTU: an embedded fieldbus port for connection to a PLC or building management system without an extra adapter.

Pump and fan duties at 37 kW

Centrifugal pumps and fans are variable-torque loads, so power falls steeply as speed falls. That is why most 37 kW pump and fan applications are sized on the light-duty rating of 68.4 A. Conveyors, mixers, positive displacement pumps and crushers start against high torque and should be checked against the heavy-duty figure of 61 A and the 150% overload allowance instead. If the motor nameplate current sits close to either limit, step up a size rather than running the drive at its edge.

Installation and commissioning notes

The R4 frame is wall-mounted and cooled by forced air, so leave the free space above and below that the hardware manual specifies and make sure the 150 m³/h of cooling air can actually leave the enclosure. With 858 W of typical losses, a sealed cabinet without ventilation or air conditioning will overheat quickly.

  • Use the recommended input fuses (IEC 100 A gG) to keep the protection coordinated with the drive.
  • Use a symmetrical shielded motor cable, ground the shield at both ends with 360° glands and keep it within the 300 m maximum.
  • Run control and fieldbus cables away from motor cables, crossing at right angles where unavoidable.
  • Enter motor nameplate data accurately before the first start and run the identification routine when the application allows.

Derating for heat and altitude

The catalogue ratings apply at a stated reference ambient. Above that temperature, or at high altitude, output current must be derated according to the ABB hardware manual. In hot climates this is not a formality; it should be part of the sizing calculation.

Operating in Oman and the GCC

Water pumping stations, district cooling, HVAC air handling units and process plants across the region commonly use drives in the 30 to 45 kW range. Summer temperatures in equipment rooms often exceed what an IP21 drive is designed for unless the room is cooled, and fine dust can block heat sinks. Plan for filtered or conditioned air, clean the heat sink at regular intervals and consider a higher-rated enclosure or a cabinet solution where the drive is in a dusty plant area.

Information for your RFQ

  • Type designation ACS580-01-073A-4 and any option codes required.
  • Motor nameplate data: power, current, voltage, speed.
  • Load type (pump, fan, conveyor, mixer) and whether light or heavy duty applies.
  • Required enclosure class and installation ambient.
  • Fieldbus requirement beyond the embedded Modbus RTU.
  • Quantity and delivery location.

Source document and quotation

Seven Star LLC can quote the ACS580-01-073A-4 from Muscat. Attach the motor nameplate, supply voltage and any fieldbus requirement to the RFQ. The linked ABB ACS580 catalogue (3AUA0000145061) is the reference for the numbers shown here.

Please confirm the complete ordering code, the enclosure class, and whether site conditions require derating from the 40 degrees C and 1000 m catalogue basis before placing an order.

Datasheets & Documents
  • PDF Catalog ABB ACS580 General Purpose Drives Catalog (3AUA0000145061) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.

Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.

ABB product families on this page

Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.

Where ABB instruments and drives are used

Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.

Ordering ABB parts: what we need

For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.

Frequently Asked Questions

What nominal current does the ACS580-01-073A-4 have?
The catalogue lists 73 A at 400 V in no-overload use for 37 kW, with 68.4 A light duty and 61 A heavy duty.
What fuse does ABB recommend for the ACS580-01-073A-4?
The catalogue recommends 100 A gG fuses for IEC installations and 90 A UL Class T fuses.
How much heat and cooling air does the ACS580-01-073A-4 need?
The catalogue gives a typical heat dissipation of 858 W and 150 m3/h (88 ft3/min) of cooling air, with a maximum noise level of 70 dBA.
Which frame size and weight is the ACS580-01-073A-4?
It is frame R4, 636 mm with glandbox x 203 x 257 mm in IP21 form, weighing 19 kg.
How is the IP55 version of the ACS580-01-073A-4 ordered?
Add the option code +B056 to the type designation. The catalogue lists +B056 as the IP55 / UL Type 12 unit for frames R1 to R9.