Micro Motion TA-Series Tantalum Coriolis Flow and Density Meters

Description

Tantalum Coriolis meters for corrosive process fluids

The Micro Motion TA-Series is a family of Coriolis flow and density meters with all wetted parts made of tantalum, aimed at corrosive applications where stainless steel and nickel alloys are not suitable. The sensor measures mass flow, volume flow, density and temperature, and it is offered only with the Micro Motion 5700 field-mount transmitter, which supplies the wide range of input and output options and the Smart Meter Verification diagnostics that can detect corrosion and other process effects.

Technical specifications

Parameter Specification
Datasheet PS-002121, Rev I, March 2025
Sensor models TA010T (0.10 in), TA025T (0.25 in), TA050T (0.5 in), TA075T (0.75 in), TA100T (1 in), TA200T (2 in), TA300T (3 in, DN80)
Wetted material Pure tantalum; case in 300-series stainless steel (standard N, P, G or enhanced E, T case options)
Liquid mass and volume flow accuracy ±0.10%; repeatability ±0.05%
Liquid density accuracy ±1 kg/m3 (±0.001 g/cm3); repeatability ±0.5 kg/m3
Temperature accuracy ±1.5 °C ±0.5% of reading (case N/P/G); ±1 °C ±0.5% of reading (case E/T)
Nominal flow rate (case N/P/G) TA010T 325 kg/h; TA025T 1,130; TA050T 3,000; TA075T 5,200; TA100T 13,700; TA300T 80,000 kg/h
Nominal flow rate (case E/T) TA010T 330 kg/h; TA025T 1,150; TA050T 3,650; TA075T 5,250; TA100T 14,250; TA200T 20,000; TA300T 74,000 kg/h
Zero stability TA010T 0.035 kg/h to TA300T 6.5 kg/h
Maximum working pressure (case E/T) 580 psig (40 barg) for TA010T to TA200T; 232 psig (16 barg) for TA300T; connection de-ratings apply
Process temperature -40 °F to 356 °F (-40 °C to 180 °C); extended-mount junction box above 176 °F (80 °C)
Ambient temperature -40 °F to 176 °F (-40 °C to 80 °C)
Sensor weight From 5 kg (TA010T) to 56 kg (TA300T), depending on case option (CL150 flange, without electronics)
Hazardous area CSA C-US; ATEX II 1/2G Ex ib IIC T6 to T3 Ga/Gb; IECEx Ex ib IIC T6 to T3 Ga/Gb
Other standards PED, SIL2 and SIL3 safety certifications; Model 5700 transmitter housing NEMA 4X (IP66)

Where tantalum is chosen

Tantalum is selected for strongly corrosive fluids, typically hot acids, where the sensor would otherwise be limited by material compatibility. General corrosion tables do not account for cyclic stress, so the datasheet advises checking the Micro Motion Corrosion Guide for the actual fluid and concentration. Because the sensor is tied to the 5700, the transmitter brings Smart Meter Verification, an onboard historian and multi-channel I/O. The Micro Motion 5700 is covered on its own page: Micro Motion 5700 Coriolis flow transmitter. Process connections follow ASME B16.5 and EN 1092-1 per the de-rating charts.

What to confirm before ordering

  • Exact fluid, concentration and temperature for a tantalum compatibility check
  • Sensor size, case option (N, P, G, E or T) and process connection with rating
  • Process temperature, because the extended-mount junction box is needed above 176 °F (80 °C)
  • Hazardous area approval and the 5700 transmitter output configuration
  • Pressure de-rating of the selected flange at operating temperature

How the Micro Motion TA-Series works

A Coriolis meter measures mass flow directly. The fluid passes through tubes that are made to vibrate. The moving mass twists the tubes slightly, and sensors measure the twist. The twist gives the mass flow, and the tube frequency gives the density. In the TA-Series the tubes and every part that touches the fluid are made of tantalum, a metal that resists many strong acids. A transmitter turns the signals into flow, density and temperature outputs.

Where the Micro Motion TA-Series is used

  • Hot acid service
  • Chemical process lines
  • Corrosive fluids that damage stainless steel
  • Fluids that damage nickel alloys
  • Batching and transfer of aggressive liquids

Selection checklist for the Micro Motion TA-Series

  • Sensor size from TA010T to TA300T
  • Nominal flow rate
  • Case option, standard or enhanced
  • Process temperature up to 180 degrees C
  • Working pressure and connection rating
  • Hazardous area marking
  • Model 5700 transmitter outputs
  • Corrosion diagnostics

Installation, commissioning and maintenance notes for the TA-Series

Install the sensor so that it stays full of liquid and support the pipework so that no load falls on the sensor. Mount the Model 5700 transmitter, wire the cable and configure the outputs. Zero the meter with no flow. Use the meter verification diagnostics to check the meter over time.

Requesting a quotation for the Micro Motion TA-Series

Please send the fluid, the flow, the temperature, the pressure, the connection and the quantity. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

TA-Series accuracy

Liquid mass and volume flow accuracy is plus or minus 0.10 percent. Repeatability is plus or minus 0.05 percent.

TA-Series density

Density accuracy is plus or minus 1 kg/m3.

TA-Series sizes

Sensors run from TA010T at 0.10 in up to TA300T at 3 in.

TA-Series pressure and temperature

Pressure reaches 40 barg for most sizes. Process temperature runs from minus 40 to plus 180 degrees C.

TA-Series transmitter

The sensor works only with the Micro Motion 5700 field-mount transmitter.

Meter records for the TA-Series

Record the zero value, the verification results and the date.

Choosing the right TA-Series size

Choose the size from the flow rate and the pressure drop you can accept.

TA-Series tantalum wetted parts

Tantalum resists hot acids that attack stainless steel and many nickel alloys, which is why this series exists.

TA-Series measured outputs

The meter reports mass flow, volume flow, density and temperature from one sensor.

TA-Series hazardous area options

The data sheet lists CSA, ATEX and IECEx marks, so check the marking against the area classification of your site.

Documents and quotation

The Micro Motion TA-Series datasheet (PS-002121 Rev I, March 2025) is available from the product documents on this page. Seven Star LLC is an independent supplier in Muscat; send the complete order code from the nameplate or your specification and we will check it against the manufacturer documentation before quoting. Browse more flowmeters in the catalogue.

Datasheets & Documents
  • PDF Datasheet Micro Motion TA-Series datasheet PS-002121 Rev I (March 2025) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Coriolis flow and density meters have carried the Micro Motion name since 1977, when the company started in Boulder, USA. A Coriolis meter measures mass flow directly and reads density from the same tubes. Seven Star LLC, an independent supplier in Oman, lists the Micro Motion ELITE CMF400 Coriolis flow and density meter and the compact G-Series, and sources Micro Motion flow meters by complete model code.

Micro Motion meter families

ELITE is the manufacturer's top performance family for flow and density, and the CMF400 is one of its larger line sizes. The G-Series is a newer, very compact family for general duty. Each sensor is paired with a Coriolis transmitter, and the range also includes density and viscosity meters. Liquids, gases and slurries can all be measured, which is why these meters appear in oil and gas, refining, chemical, food and marine service.

Ordering Micro Motion meters: what we need

A Micro Motion sensor and its transmitter each have their own model code and serial number; send both. For a new meter we need the fluid, flow range, density, viscosity, operating pressure and temperature, line size, process connection and rating, wetted material, hazardous area approval, outputs and protocol. Custody transfer duty in the GCC should be stated up front because it changes the approvals and calibration options requested.

Frequently Asked Questions

What are the wetted materials of the TA-Series?
All wetted parts are pure tantalum, which is intended for corrosive process fluids; check compatibility against the manufacturer corrosion guide.
Which transmitter does the TA-Series use?
The datasheet states the TA-Series is available only with the Micro Motion 5700 field-mount transmitter.
What accuracy is stated?
Liquid mass and volume flow accuracy of ±0.10% with ±0.05% repeatability, and density accuracy of ±1 kg/m3.
What process temperature range applies?
From -40 °F to 356 °F (-40 °C to 180 °C), with the extended-mount junction box required above 176 °F (80 °C).
Is the TA-Series suitable for safety instrumented systems?
The datasheet lists SIL2 and SIL3 safety certifications under industry standards; confirm the certified configuration for your meter and transmitter.