- Industrial Communications
- AC Drives
- Vibration Monitoring
- PLC & I/O Cards
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Encoders
- Industrial Computers
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Servo Drives
- Automation Software
- Robotics
- Machine Vision
Brand: MOXA
Moxa EDS-G509 9-Port Full Gigabit Managed Ethernet Switch
Description
Why the EDS-G509 suits control-network edge and ring duty
EDS-G509 is listed by Moxa as: Industrial full Gigabit Ethernet switch with 4 10/100/1000BaseT(X) ports, 5 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slot combo ports, 0 to 60°C operating temperature. A nine-port managed switch with all ports at Gigabit speed (four 10/100/1000T(X) plus combo ports) for backbones that carry video, SCADA and historian traffic together.
Key figures from the Moxa page: the power input is 12/24/48 VDC; Redundant dual inputs; operating temperature is 0 to 60°C (32 to 140°F); dimensions are 87.1 x 135 x 107 mm (3.43 x 5.31 x 4.21 in); weight is 1510 g (3.33 lb); the enclosure is rated IP30.
Standards and approvals printed for this model include marine approvals (ABS; DNV; LR; NK); railway standard EN 50121-4; safety standard EN 62368-1; UL 508. Approvals can differ between variants of a series, so check the one on the exact order code.
Technical specifications
| Parameter | Specification |
|---|---|
| Alarm Contact Channels | 2; Relay output with current carrying capacity of 1 A @ 24 VDC |
| Digital Input Channels | 2 |
| Digital Inputs | +13 to +30 V for state 1; -30 to +3 V for state 0; Max. input current: 8 mA |
| 10/100/1000BaseT(X) Ports (RJ45 connector) | 4; Auto negotiation speed; Full/Half duplex mode; Auto MDI/MDI-X connection |
| Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+) | 5 |
| Filter | 802.1Q VLAN; GMRP; GVRP; IGMP v1/v2; Port-based VLAN |
| Industrial Protocols | EtherNet/IP; Modbus TCP |
| Management | Back Pressure Flow Control; BOOTP; DDM; DHCP Option 66/67/82; DHCP Server/Client; Flow control; IPv4/IPv6; LLDP; Port Mirror; RARP; RMON; SMTP; SNMP Inform … |
| Redundancy Protocols | Link Aggregation; MSTP; RSTP; STP; Turbo Chain; Turbo Ring v1/v2 |
| Security | Broadcast storm protection; HTTPS/SSL; Port Lock; RADIUS; SSH; TACACS+; SNMPv3 |
| Time Management | NTP Server/Client; SNTP |
| IGMP Groups | 256 |
| MAC Table Size | 8 K |
| Max. No. of VLANs | 64 |
| Packet Buffer Size | 1 Mbits |
| Priority Queues | 4 |
| VLAN ID Range | VID 1 to 4094 |
| Console Port | RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1) |
| DIP Switches | Turbo Ring, Master, Coupler, Reserve |
| Power Connector | 2 removable 6-contact terminal block(s) |
| Input Current | 0.69 A @ 24 VDC |
| Input Voltage | 12/24/48 VDC; Redundant dual inputs |
| Operating Voltage | 9.6 to 60 VDC |
| Overload Current Protection | Supported |
| Reverse Polarity Protection | Supported |
| Housing | Metal |
| IP Rating | IP30 |
| Dimensions | 87.1 x 135 x 107 mm (3.43 x 5.31 x 4.21 in) |
| Weight | 1510 g (3.33 lb) |
| Installation | DIN-rail mounting; Wall mounting (with optional kit) |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Safety | EN 62368-1; UL 508 |
| EMC | EN 55032/35 |
| EMI | CISPR 32, FCC Part 15B Class A |
| EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV; IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m; IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV; IEC 61000-4-5 Surge: Power: 2 … |
| Railway | EN 50121-4 |
| Vibration | IEC 60068-2-6 |
| Shock | IEC 60068-2-27 |
| Freefall | IEC 60068-2-32 |
| Maritime | ABS; DNV; LR; NK |
| Warranty Period | 5 years |
Selecting the right variant
It is used as a ring or core node in plants where Fast Ethernet is no longer enough, for example refinery control networks and large water treatment works.
On the practical side, mounting is listed as din-rail mounting; wall mounting (with optional kit); the housing is metal; the stated MTBF is 598,659 hrs; the warranty period is 5 years. Treat the MTBF as a manufacturer prediction under its stated method, not a guarantee for your site.
Before ordering, confirm which ports are copper and which take SFP modules, and the supply and temperature version. Seven Star LLC is an independent supplier in Muscat and quotes against the exact code you give us.
Installing the EDS-G509 in a control cabinet
Mount the switch on a DIN rail inside a cabinet or, where the panel layout requires it, on a wall with the optional kit. Leave enough space around the metal housing for air to move and for patch cords and fibre to bend without strain. Feed the two removable terminal blocks from separate 12/24/48 VDC sources if redundant power is part of the design, and wire one of the alarm relay outputs to the PLC or an indicator so that a lost supply or link fault is noticed immediately.
Label every copper and fibre connection at both ends before commissioning. On a nine-port node used as a ring or core switch, clear labelling saves time later when a link must be traced quickly during a fault.
Configuration and commissioning
Use the management access described in the user manual and set secure login details before the switch is joined to the plant network. Set the IP address, time synchronisation via NTP or SNTP, SNMPv3 and the user accounts required by site policy, and disable services that are not needed.
Plan VLANs so that control, video and historian traffic are separated, and use the priority queues to protect time-critical control messages. If the switch is part of a Turbo Ring or RSTP ring, set the ring roles with the DIP switches or software as the design specifies, then test recovery by disconnecting one ring link while monitoring a running process. Save the final configuration and keep a backup copy offline.
Operating environment in Oman and the GCC
The 0 to 60°C operating range and IP30 rating make this a switch for the inside of a protected cabinet. Outdoor kiosks and substation panels in Oman can exceed 60°C internally during summer if they stand in the sun without shading or cooling, so measure or calculate the cabinet temperature rather than relying on outdoor air figures.
Humidity must stay non-condensing, which matters in coastal plants where hot humid air meets an air-conditioned panel. Keep cabinet doors sealed against sand and dust, cover unused ports, and keep fibre connectors capped until they are used, since dust on a fibre end face is a common cause of link errors.
Maintenance and network health
Review the event log, port statistics and DDM readings for fibre links at regular intervals; a rising error count or falling optical level often gives warning before a link fails. Check power and alarm wiring during planned shutdowns, and keep firmware and configuration changes under change control so the network can be returned to a known good state.
Documents and quotation
The attached file is Moxa’s published datasheet for the family (moxa-eds-g509-series-datasheet-v1.4). For a quotation, send the full order code, the quantity required and where the goods are to be delivered.
More products in this range: Industrial Communications.
Datasheets & Documents
- Datasheet Moxa EDS-G509 series datasheet v1.4 Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Since 1987 Moxa, based in New Taipei City, Taiwan, has built networking hardware for places where an office switch would fail: substations, wellhead panels, roadside cabinets. Seven Star LLC lists Moxa industrial Ethernet switches and fiber converters and supplies Moxa networking devices to system integrators and plant teams in Oman as an independent supplier. Each request is checked against the full Moxa model name before we quote.
Moxa switches and converters listed here
The EDS-G508E is a managed switch with eight Gigabit ports from the EDS managed line. The EDS-316-MM-SC-T is a 16-port unmanaged switch with 14 copper ports, two multi-mode SC fiber ports and the wide-temperature option (-40 to 75 C). The TCF-142-S-SC-T belongs to the TCF-142 series, which converts RS-232/422/485 serial signals to single-mode fiber. Moxa also makes serial device servers, protocol gateways, wireless devices and industrial computers, used on SCADA and telemetry networks across the GCC.
Ordering Moxa devices: what we need
The suffixes carry the specification. Send the complete model name, including fiber mode and connector (MM-SC, SS-SC, ST), the -T wide-temperature suffix and any coating or approval suffix. Add the power supply voltage, the SFP modules needed and the quantity.
Browse MOXA products by category: Industrial Communications.
Related products
Frequently Asked Questions
Moxa lists it as: Industrial full Gigabit Ethernet switch with 4 10/100/1000BaseT(X) ports, 5 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slot combo ports, 0 to 60°C operating temperature. A nine-port managed switch with all ports at Gigabit speed (four 10/100/1000T(X) plus combo ports) for backbones that carry video, SCADA and historian traffic together.
The Moxa specification gives an input voltage of 12/24/48 VDC; Redundant dual inputs. Check the terminal arrangement and, where relevant, the redundant-input wiring against your panel supply before ordering.
The listed operating temperature is 0 to 60°C (32 to 140°F). Wide-temperature versions carry a -T suffix in Moxa's order codes where the series offers them, and they are separate order codes.
It is an unmanaged switch: ports auto-negotiate speed and crossover, so it works as plug-and-play without software configuration, and any alarm or switch functions are set on the unit itself.
You can download the Moxa datasheet from this page. For a quotation, send us the full order code, quantity and destination; Seven Star LLC is an independent supplier based in Muscat.

Reviews