Brand: ABB
ABB ACH580-01-062A-4 HVAC AC Drive 30 kW 62 A
Description
Where the ACH580-01-062A-4 fits in a building
Rated 30 kW with 62 A of nominal output current, the ACH580-01-062A-4 belongs to ABB’s ACH580-01 range, the wall-mounted HVAC line with BACnet MS/TP, Modbus RTU and N2 built in. It occupies frame R4. At 30 kW it opens frame R4 and suits big fan walls and chilled-water pumps. ABB positions the family for fans, pumps and also for basic constant-torque duties such as compressors.
Among the HVAC features in the control program are four start interlocks, belt-loss (under-load) detection, real-time clock scheduling and PID controllers for process control. Related products are in AC drives and on the ABB ACS580 page.
Technical specifications
| Parameter | Specification |
|---|---|
| Order type | ACH580-01-062A-4 |
| Family and mounting | ACH580 HVAC series, 01 = wall-mounted |
| Mains voltage class | Three-phase 380 to 480 V, code 4 |
| Frame | R4 |
| Nominal output at 400 V | 30 kW, 62 A |
| Light-duty output at 400 V | 58 A, 30 kW |
| Light-duty output at 480 V | 52 A, 40 hp |
| Protection class | IP21 (UL Type 1), or IP55 (UL Type 12) via +B056 |
| IP21 height, width, depth | 636 mm with gland box (636 mm without) x 203 x 257 mm |
| Mass in IP21 | 19 kg |
| IP55 size and mass | 636 x 203 x 265 mm, 20 kg |
| Adjacent catalogue types | Below: ACH580-01-046A-4 (22 kW); above: ACH580-01-073A-4 (37 kW) |
Duty ratings of the ACH580-01-062A-4
Start from 58 A: this is the continuous light-duty current at 400 V, enough for a 30 kW fan or pump motor, with 110% for one minute (about 63.8 A, derived). If the motor is wound for 460 V or 480 V, read the 52 A, 40 hp column instead. The nominal 62 A figure is for loads without any overload demand.
The catalogue dimension table lists 636 x 203 x 257 mm and 19 kg for IP21 frame R4 (the 636 mm height applies without the gland box). IP55 is 636 x 203 x 265 mm and 20 kg. With a main switch or C1 filter variant the IP55 body becomes 879 x 206 x 286 mm and 23.3 kg.
The catalogue’s SynRM selection guide matches this drive with 22 kW M3BL180MLA4 at 3000 rpm (50.0 A nominal, motor efficiency 94.0%, package efficiency 91.6%); 22 kW M3BL200MLF4 at 1500 rpm (49.1 A nominal, motor efficiency 94.5%, package efficiency 92.2%). Read the package efficiency as a calculated value for the drive and motor together, useful when comparing options but not a substitute for the motor’s own datasheet.
Type code and option codes
The designation breaks down as series ACH580, construction 01 (wall-mounted), size 062A and voltage code 4 for 380 to 480 V. ABB lists these additions, among others: +F278 for a main disconnect switch with auxiliary contact, +F316 for the disconnect switch plus a C1 filter, +C135 for flange mounting and +L501 for the CMOD-01 relay and 24 V module.
Add a fieldbus only when the building network needs one: ControlNet via FCNA-01 (+K462), EtherCAT via FECA-01 (+K469) and POWERLINK via FEPL-02 (+K470) are among the choices.
Standard equipment and limits listed by ABB: altitude derating of 1% per 100 m between 1000 and 4000 m, coated circuit boards, a DC choke built to IEC 61000-3-12, Safe Torque Off certified to SIL 3 / PL e and an EMC category C2 design for frames R1 to R9.
Documentation and quotation
Request the ACH580-01-062A-4 from Seven Star LLC with your motor nameplate, supply voltage and communication needs; the quotation gives availability and lead time. Ratings, dimensions, motor pairing and option codes on this page were taken from ABB catalogue 3AUA0000186691, revision F (9.14.2019), available via the document link.
Confirm before ordering: type code and plus options, motor rated current, enclosure class, ambient temperature and altitude, and any change in newer ABB documents.
Datasheets & Documents
- ach580cat Catalog Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.
Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.
ABB product families on this page
Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.
Where ABB instruments and drives are used
Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.
Ordering ABB parts: what we need
For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.
Related products
Frequently Asked Questions
ABB lists 58 A for 30 kW on a 380 to 415 V network and 52 A for 40 hp on a 440 to 480 V network, with a nominal rating of 62 A.
It is frame R4. In IP21 it weighs 19 kg and measures 203 x 257 mm in width and depth; the IP55 version weighs 20 kg.
Add the plus code +B056 to the type designation. The catalogue calls it the IP55 unit for wall-mountable drives and lists 636 x 203 x 265 mm for frame R4.
BACnet MS/TP, Modbus RTU and N2 are included as standard. BACnet/IP and other networks need an F-series adapter, for example FBIP-21 with +K465.
The catalogue lists ACH580-01-062A-4 as matched drive for 22 kW M3BL180MLA4 at 3000 rpm; 22 kW M3BL200MLF4 at 1500 rpm.

Reviews