SKF LAGD 125/WA2 SYSTEM 24 Gas Driven Lubricator, ATEX
Description
A gas driven lubricator that needs no power and no tools to set
The SKF LAGD 125/WA2 belongs to the SKF SYSTEM 24 LAGD series of gas driven single point automatic lubricators. The 125 ml unit is filled with SKF LGWA 2, the high load, extreme pressure, wide temperature range grease, and is supplied ready to use. Tool-free activation and time setting allow easy and accurate adjustment of lubricant flow, with a dispense period adjustable from 1 to 12 months.
A gas cell produces inert gas that pushes a specially shaped piston, so no battery or mains supply is needed; the unit can be stopped or adjusted if required. A transparent lubricant container allows visual inspection of the dispense rate, and the compact size suits restricted installations. SKF lists applications in restrictive and hazardous locations, bearing housings, electric motors, fans and pumps, conveyors and cranes.
Technical specifications
| Parameter | Specification |
|---|---|
| Lubricant in this unit | LGWA 2 grease, 125 ml (4.2 US fl. oz) |
| Nominal emptying time | Adjustable, 1 to 12 months |
| Drive mechanism | Gas cell producing inert gas |
| Ambient temperature range | -20 to +60 C (-5 to +140 F) |
| Maximum operating pressure | 5 bar (75 psi) at start-up |
| Connection thread | R 1/4 |
| Maximum feed line length with grease | 300 mm (11.8 in.) |
| Protection class | IP 68 |
| Intrinsically safe approval | II 1G Ex ia IIC T6 Ga; II 1D Ex ia IIIC T200 85 C Da; I M1 Ex ia I Ma |
| EC type examination certificate | DEKRA 21ATEX0015 X |
| Weight (LAGD 125) | Approx. 200 g (7.1 oz) |
| Recommended storage temperature | 20 C (70 F) |
| Storage life of lubricator | 2 years |
Variants and accessories
The same series offers 60 and 125 ml units with other lubricants. In the 125 ml size SKF lists LAGD 125/WA2, LAGD 125/EM2, LAGD 125/GB2 (biodegradable grease), LAGD 125/HB2, LAGD 125/HQ2, LAGD 125/WM2, LAGD 125/FG2 and LAGD 125/FQ2 (food grade, NSF H1 greases), plus chain oils and an empty unit for oil filling (LAGD 125/U). The 60 ml size has its own set of codes, such as LAGD 60/WA2. Accessories include angle connections, extensions, nipples, tube connections, flexible tubes, brushes, a clamp, a protection base and a cap. SKF DialSet helps to calculate the correct dispense rate.
Selecting and installing
Do not choose a setting longer than 6 months when the ambient temperature is constantly between 40 and 60 C, because SKF advises this for optimum performance. Grease feed lines are limited to 300 mm. The unit mounts on an R 1/4 thread, and adapter nipples cover other threads. For electro-mechanical alternatives see the SKF TLSD listing; related items sit under Electric Motors. For hazardous areas, compare the marking above with the zone classification and approval your site requires.
Fit the unit by screwing it onto the R 1/4 connection or an adapter nipple, then activate it and set the dial. Replace the lubricator when it is empty, and do not use it beyond its 2 year storage life. SKF gives a separate note for constant ambient temperatures between 40 and 60 C.
Why single point automatic lubrication helps
Manual greasing with a grease gun depends on people reaching every point at the right interval with the right quantity. In practice, some bearings receive too much grease, others too little, and points that are hard or unsafe to reach are often missed. A single point automatic lubricator such as the LAGD 125/WA2 delivers small amounts of grease continuously over the chosen period, which keeps a steadier lubricant film in the bearing and reduces the risk of contamination entering between manual services.
It also reduces the number of times technicians need to approach running machinery, climb to elevated points or enter restricted areas. This is a practical benefit on conveyors, fans, pumps and motors spread across a large site, and on cranes or equipment where access requires a permit or shutdown.
Why LGWA 2 grease
SKF LGWA 2 is described above as a high load, extreme pressure, wide temperature range grease. These properties suit rolling bearings in general industrial machinery that see moderate to heavy loads, occasional shock and varying temperatures, such as conveyor pulleys, fan bearings and pump bearings. Where the existing bearing grease is different, compatibility should be checked before switching, and where a food grade or biodegradable grease is required, one of the other codes listed in the series should be considered instead.
Selecting the dispense period
The correct setting depends on the bearing size, speed, load, temperature and the amount of grease the bearing needs over time. SKF DialSet, mentioned above, helps calculate an appropriate rate, and the result can be compared with the available settings. Ambient temperature has an important influence on a gas driven unit, so the SKF note on high constant ambient temperatures should be respected. Choosing a setting and recording the activation date on the unit makes it easier to plan replacement before the lubricator is empty.
Installation and inspection practice
Before fitting, make sure the lubrication point and the grease path to the bearing are clean and free of hardened old grease, and that the point accepts grease without excessive resistance. Mount the lubricator directly where possible, or within the stated feed line limit, so that the gas pressure can move the grease reliably. During routine inspection rounds, the transparent container allows staff to check that the lubricant level is falling as expected; a level that does not change can indicate a blocked point.
Use in hazardous and hot areas in Oman and the GCC
Oil and gas, petrochemical and mining facilities in the region often have pumps, fans and motors in classified hazardous areas. The intrinsically safe marking and EC type examination certificate listed above allow the lubricator to be evaluated for these zones without the need for an electrical supply. Site engineers should still confirm that the marking matches the area classification.
High summer temperatures are common, particularly on outdoor equipment exposed to sun, so the ambient temperature range and the SKF advice on hot conditions should be taken into account when choosing the dispense period. Store spare lubricators in a cool place, close to the recommended storage temperature, and use them within their storage life.
Documents and quotation
The SKF leaflet with the full ordering list is attached. Send the exact code, quantity and delivery point, and we will return a quotation.
Datasheets & Documents
- Datasheet SKF SYSTEM 24 LAGD series leaflet (PUB MP/P8 12666/5 EN, January 2022) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SKF is the Swedish bearing manufacturer founded in Gothenburg in 1907. The company was built on the self-aligning ball bearing developed by engineer Sven Wingquist, who became its first managing director. Today SKF also makes seals, lubrication systems, condition monitoring equipment and maintenance tools.
Seven Star LLC is an independent supplier in Muscat. We list SKF bearings, greases, automatic lubricators, condition monitoring sensors and maintenance tools, and supply them to maintenance teams in Oman and the GCC by designation.
SKF company profile
| Established | 1907, Gothenburg, Sweden; first factory built in 1908 |
|---|---|
| Founding product | Sven Wingquist's self-aligning ball bearing |
| Name | From Svenska Kullagerfabriken, Swedish for "Swedish Ball Bearing Factory" |
| Product families | Rolling bearings, seals, lubricants and lubrication systems, condition monitoring sensors and analysers, and maintenance tools for mounting, alignment and dismounting |
Milestones
- 1907: Sven Wingquist's self-aligning ball bearing is patented and SKF is founded in Gothenburg.
- 1908: The first factory is built.
- 1912: SKF is represented in 32 countries.
- 1926: SKF sets up AB Volvo as a subsidiary to build cars; the first production car follows in 1927.
- 1935: Volvo becomes an independent company.
SKF products we list
| Family | Models | Typical use |
|---|---|---|
| Bearings | 6205-2RSH/C3, 6206-2RS1, 6314, 7312 BECBM | Motors, pumps, fans and gearboxes |
| Greases | LGMT 2, LGMT 3, LGEP 2, LGWA 2, LGHP 2, LGHB 2, LGEV 2 | General, heavy-load, high-temperature and slow-speed bearing lubrication |
| Automatic lubrication | TLSD, LAGD 125 (ATEX), TLMR, TLMP 1008, TLGH 1 grease gun | Steady greasing of hard-to-reach or many lubrication points |
| Condition monitoring | Microlog Analyzer AX, CMSS 2200, CMSS 793-EE (ATEX), TKRS 21 stroboscope, TKRT 31 tachometer | Vibration routes, permanent sensors and speed checks |
| Alignment | TKSA 41 shaft alignment, TKBA 40 belt alignment, TMAS shims | Laser alignment of couplings and belt drives |
| Mounting and dismounting | TIH 030m, TIH 100m, TIH 220m heaters, TMFT 36, TMMA 75H, TMMP 10, TMHP 30/170 pullers, TMJL 100 pump | Fitting and removing bearings without damage |
An SKF designation describes the bearing exactly. In 6205-2RSH/C3, "62" is a light-series deep groove ball bearing, "05" means a 25 mm bore (05 × 5), "2RSH" means rubber seals on both sides, and "C3" means internal clearance larger than normal, which motors often need because the inner ring runs warmer than the outer. Choosing the right grease matters just as much: a general grease such as LGMT 2 suits most motors, while heavy loads, high temperatures or slow speeds need an EP, high-temperature or high-viscosity grade.
Where SKF products are used
In Oman and the GCC, SKF bearings, lubricants and tools are used by maintenance teams in oil and gas, power and desalination, cement, mining, steel, water and food plants, and by motor and pump repair workshops.
Ordering SKF products: what we need
Send the full bearing designation including all suffixes (seals, clearance, cage), and the quantity. For greases, send the grade and pack size. For tools and lubricators, send the model and, for heaters, the largest bearing weight and bore you need to heat.
Facts checked against SKF company history, October 2026.
Browse SKF products by category: Electromotors.
Related products
Frequently Asked Questions
By a gas cell that produces inert gas and pushes the piston, so no electrical supply is needed.
From 1 to 12 months, adjustable without tools.
SKF LGWA 2 high load, extreme pressure, wide temperature range grease, 125 ml.
II 1G Ex ia IIC T6 Ga, II 1D Ex ia IIIC T200 85 C Da and I M1 Ex ia I Ma, certificate DEKRA 21ATEX0015 X.
-20 to +60 C, with an IP 68 protection class.