- Industrial Communications
- AC Drives
- Vibration Monitoring
- PLC & I/O Cards
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Encoders
- Industrial Computers
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Servo Drives
- Automation Software
- Robotics
- Machine Vision
Brand: ABB
ABB ACS580-01-206A-4 ACS580 110 kW Frame R7 AC Drive
Description
ACS580-01-206A-4: frame R7 drive for heavy pumps and fans
Where a motor of 110 kW needs adjustable speed on a 400 V supply, the ACS580-01-206A-4 offers 206 A of nominal current in frame R7. ABB builds it for water, HVAC-style and industrial machinery work, with the common ACS580 control program.
It ships as IP21; the IP55 version is selected at order time with a plus code and cannot be added later.
Technical specifications
| Parameter | Specification |
|---|---|
| Order code | ABB ACS580-01-206A-4 |
| Product line | ACS580-01 general purpose drive, wall-mounted |
| Frame | R7 |
| Supply voltage | 3-phase 380 to 415 V (400 V rating), 380 to 480 V range |
| Rated current | 206 A |
| Rated motor power | 110 kW |
| Light-duty rating | 196 A, 110 kW |
| Heavy-duty rating | 169 A, 90 kW |
| Peak current | 287 A |
| Mains current | 206 A |
| IP21 body | 284 x 880 x 370 mm, 54 kg |
| IP55 option (+B056) | 284 x 880 x 381 mm, 56 kg |
| Heat, airflow and sound | 2310 W / 450 m3/h / 67 dB(A) |
| Fuse, gG | 315 A, OFAF1H315 (size 1) |
| Fuse, aR | 350 A, Bussmann 170M3818 |
| Fuse, UL | JJS-300 |
| Cu cable, IEC | 3×150+70 mm2 |
| Included as standard | Choke, internal EMC C2 filter, Safe torque off, assistant control panel, coated boards |
| Braking chopper | Not built in |
| Environment | -15 to +50 C operation; up to 4000 m with derating above 1000 m |
Choosing the overload class
For heavy-duty operation the drive provides 169 A (90 kW) at 150% overload for one minute in ten; light duty is 196 A (110 kW) at 110%. The maximum output current is 287 A for two seconds at start.
With a mass of 54 kg this frame R8 drive is a two-person lift unless a hoist is used. The IP21 body is 284 mm wide, 880 mm high and 370 mm deep; ABB lists 2310 W of loss, 450 m3/h of cooling air and 67 dB(A). Suitable fuses: 315 A OFAF1H315 (gG), 350 A 170M3818 (aR) or JJS-300 for UL. Cable: 3×150+70 mm2 copper per phase.
Free space for frame R8 is 155 mm above, 300 mm below and 150 mm beside the drive, and ABB’s R8 terminals accept two cables per phase of up to 150 mm2 each.
Reading the ACS580-01-206A-4 order code
ABB’s key for ACS580-01-206A-4 lists plus codes for control panels (+J400, +J425, +J429, +J404), I/O (+L501, +L512, +L523), fieldbus adapters (+K454, +K457, +K451, +K473, +K475) and construction (+B056, +C135, +H358). State each one when requesting a price.
Please include the planned installation altitude, the ambient temperature range and the type of enclosure or cabinet in your request, so that derating and cooling can be checked against the manufacturer’s data before a quotation is issued.
The ACS580-01-206A-4 sits in ABB’s general purpose ACS580 range, and its assistant control panel and built-in functions are described in the manual set. Before ordering, confirm the motor current, the supply voltage, the cable length to the motor and whether an EMC category or filter is required, because these affect the type code that ABB lists.
Selection considerations for a 110 kW drive
The first decision is the duty profile of the driven machine. Centrifugal pumps and fans with a variable torque characteristic normally fit the light-duty rating, while conveyors, mixers, positive displacement pumps and other constant torque loads that need high starting torque usually call for the heavy-duty rating. Compare the motor nameplate current with the relevant drive current rather than relying on the kW figure alone, because motor efficiency, pole count and supply voltage all change the current drawn for a given power.
Also consider how the motor will be stopped. The braking chopper is not built in, so applications with high inertia or overhauling loads need their deceleration and braking requirements reviewed at the design stage.
Installation and commissioning practice
Plan the mounting location around cooling. The drive releases a significant amount of heat, and the cooling air must be able to enter and leave freely, whether the drive is wall-mounted in a plant room or built into a cabinet. Observe the free space requirements in the hardware manual, keep the enclosure ventilation sized for the stated losses, and use shielded motor cable with correct earthing practice to support the EMC performance of the installation.
Before power-up, check the supply voltage, the protective device and cable sizing against the manual. Use the assistant control panel to enter the motor nameplate data, run the motor identification routine where the application allows it, and then set ramps, speed limits and protection functions. If Safe torque off is used in the machine safety concept, test the function and document the result as part of the commissioning record.
Integration in typical plant systems
In water and wastewater stations, the drive is commonly used to hold pressure or level by varying pump speed from a process signal. In building services and industrial ventilation it controls fan speed against a pressure, flow or temperature setpoint. Control can be through the standard I/O or through one of the fieldbus adapter options, so define early whether the drive will be controlled from a PLC, a SCADA system or locally.
Operation and maintenance in GCC conditions
High ambient temperatures in Oman and the GCC reduce the cooling margin, and above the rated ambient limits derating applies as described in the manual. Dust can build up on heat-dissipating surfaces and reduce cooling, so periodic inspection and cleaning according to ABB’s maintenance schedule is important, especially for the IP21 version in dusty plant rooms. In humid coastal sites, keep the enclosure closed and avoid condensation when the drive is de-energised for long periods. Keep the parameter settings backed up so that the drive can be restored quickly after any service work.
What to include in your RFQ
List the full type code with all required plus codes, the motor data, the duty profile, the supply voltage, the enclosure class, and the installation conditions, including ambient temperature and altitude.
Documents and quotation
The attached manual (ABB ACS580-01 hardware manual, English Revision E, attached to this page) holds the full rating tables. Neighbouring sizes appear under AC Drives; the ACS580 page gives the family overview.
To avoid a mismatch, send the existing drive label, quantity and options. Seven Star LLC, independent supplier in Muscat, confirms availability when it quotes.
Datasheets & Documents
- Manual ABB ACS580-01 Hardware Manual, English, Revision E Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.
Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.
ABB product families on this page
Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.
Where ABB instruments and drives are used
Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.
Ordering ABB parts: what we need
For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.
Related products
Frequently Asked Questions
ABB lists 206 A nominal output and 110 kW for nominal use on a 400 V supply; light duty is 196 A and heavy duty 169 A.
Frame R7. The IP21 unit measures 284 x 880 x 370 mm and weighs 54 kg.
A 315 A gG fuse of type OFAF1H315, or a 350 A aR fuse 170M3818; UL installations use JJS-300.
IP55 (UL Type 12) is a factory option, +B056, which cannot be fitted later. State it on the quotation request.
It differs in current (206 A), frame (R7), cooling air (450 m3/h) and fusing, while the control program and options follow the common ACS580 platform.

Reviews