Brand: Pedrollo
Pedrollo 2CP Twin-Impeller Centrifugal Pump 1.1-11 kW
Description
Twin-impeller centrifugal pumps for high pressure from clean water: up to 112 m head
The Pedrollo 2CP series is a close-coupled centrifugal pump with two impellers in series, which lifts the head well above that of a single-impeller pump of the same size. Pedrollo lists flow up to 450 l/min (27 m3/h) and head up to 112 m on the 50 Hz datasheet, with motors from 1.1 to 11 kW, and recommends the pumps for clean water and liquids that are chemically non-aggressive towards the pump materials. Typical uses named in the datasheet are water distribution together with autoclave (pressure) tanks, increasing network pressure and fire-fighting units, in domestic, civil and industrial settings.
The series spans six frames: 2CP 25/14, 25/16, 32/200, 32/210, 40/180 and 40/200, each with two or three trims lettered A, B or C. Single-phase 2CPm versions are offered on the 25/14 and 25/16 frames; the larger frames are three-phase.
Technical specifications
| Parameter | Specification |
|---|---|
| Pump type | Close-coupled twin-impeller centrifugal pump, ISO 228/1 threaded ports |
| Flow rate | Up to 450 l/min (27 m3/h) |
| Head | Up to 112 m |
| Motor power (P2) | 1.1 to 11 kW (1.5 to 15 HP) |
| Manometric suction head | Up to 7 m |
| Liquid temperature | -10 C to +90 C |
| Ambient temperature | -10 C to +40 C |
| Maximum working pressure | 10 bar |
| Motor efficiency and protection | IE3 three-phase, IE2 single-phase; class F insulation; IPX4 (IPX5 on request for 2CP 32/200, 32/210, 40/180, 40/200) |
| Suction body and delivery port | Cast iron, ISO 228/1 threaded |
| Impellers | Brass |
| Mechanical seal | Graphite / ceramic / NBR: FN-18 (18 mm shaft) for 25/14 and 25/16; FN-20 (20 mm) for 32/200 and 32/210; FN-32 NU (32 mm) for 40/180 and 40/200 |
| Motor shaft | Stainless steel AISI 431 |
| Tolerance | Curves to EN ISO 9906, grade 3B |
Frames and duty examples from the datasheet
| Frame | Trims and motor power | Maximum head at lowest flow | Supply |
|---|---|---|---|
| 2CP 25/14 | B 1.1 kW, A 1.5 kW | 67 m (A) at the start of the curve | Single- and three-phase |
| 2CP 25/16 | C 1.1 kW, B 1.5 kW, A 2.2 kW | 68 m (A) | Single- and three-phase |
| 2CP 32/200 | C 3 kW, B 4 kW | 85 m (B) | Three-phase |
| 2CP 32/210 | B 5.5 kW, A 7.5 kW | 112 m (A) | Three-phase |
| 2CP 40/180 | C 4 kW, B 5.5 kW, A 7.5 kW | 92 m (A) | Three-phase |
| 2CP 40/200 | B 9.2 kW, A 11 kW | 106 m (A) | Three-phase |
The head values are the first point of the published table at the lowest listed flow and fall as the flow rises. Absorbed current is given per model, for example 10.5 A for the single-phase 2CPm 25/14A on 230 V and 20.0 A for the 2CP 40/200A at the lower of the two three-phase voltages. Check the exact motor current against the supply and starter.
Selection and installation notes
A twin-impeller pump suits pressure boosting where a conventional single-impeller pump would need an oversized motor. It still needs clean liquid: the brass impellers and ceramic/graphite seal are not intended for abrasive or chemically aggressive media. Keep the suction lift within 7 m and the suction line air-tight, and size any pressure tank and pressure switch for the start frequency of the motor. For fire-fighting service, confirm with the project specification whether a certified fire pump or a pressure-boosting set is required, since the datasheet describes the 2CP only as suitable for fire-fighting units.
For still higher heads at moderate flow a vertical multistage design is the usual alternative; see the Grundfos CR vertical multistage pump.
How the Pedrollo 2CP works
The motor turns two impellers in series on one shaft. The first impeller raises the pressure of the water. The second impeller raises it again. The pump then delivers a higher head than a single-impeller pump of the same size.
Where the 2CP is used
- Water distribution with pressure tanks
- Raising network pressure
- Fire-fighting units
- Domestic installations
- Civil and industrial installations
Selection checklist for the 2CP
- Flow rate
- Head
- Motor power
- Single or three-phase supply
- Liquid temperature
- Suction lift
- Frame and trim
- Mechanical seal type
Installation, commissioning and maintenance notes for the 2CP
Fix the pump on a firm, level base. Keep the suction line short and air-tight. Prime the pump before the first start. Check the motor rotation on three-phase units. Inspect the mechanical seal for leaks at regular visits.
Requesting a quotation for the Pedrollo 2CP
Please send the flow, the head and the supply you need. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
2CP pump type
It is a close-coupled twin-impeller centrifugal pump.
2CP flow
The flow runs up to 450 l/min or 27 m3/h.
2CP head
The head reaches up to 112 m.
2CP motor power
Motor power runs from 1.1 to 11 kW.
2CP suction head
The manometric suction head is up to 7 m.
2CP liquid temperature
The liquid temperature runs from minus 10 to plus 90 degrees C.
2CP ambient temperature
The ambient temperature runs from minus 10 to plus 40 degrees C.
2CP working pressure
The maximum working pressure is 10 bar.
2CP frames
Frames are 25/14, 25/16, 32/200, 32/210, 40/180 and 40/200.
2CP single-phase versions
The 2CPm single-phase versions are offered on the 25/14 and 25/16 frames.
2CP body
The suction body and delivery port are cast iron.
2CP impellers
The impellers are brass.
2CP mechanical seal
The seal is graphite, ceramic and NBR.
2CP motor shaft
The motor shaft is stainless steel.
2CP insulation class
The motor has class F insulation.
2CP port threads
The ports have ISO 228/1 threads.
2CP liquids
It suits clean water and liquids that do not attack the pump materials.
Pump records for the 2CP
Record the frame, the trim and the duty point.
Choosing the right 2CP trim
Choose the trim from the head and flow of the duty point.
Documents and quotation
The Pedrollo 2CP 50 Hz datasheet (6 pages, EN) lists performance tables, absorbed current, dimensions, weights and materials is attached to this page and is the manufacturer’s own document, not a Seven Star summary. The manual from the Pedrollo product page covers installation and use.
Before ordering confirm the frame and trim letter, single- or three-phase supply, voltage and frequency and any IPX5 requirement. Seven Star LLC, an independent supplier in Muscat, quotes the Pedrollo 2CP against your duty point and delivery requirement; send the document tag, flow, head and liquid so the right size can be confirmed before an offer is issued.
Datasheets & Documents
- Datasheet Pedrollo 2CP twin-impeller centrifugal pump datasheet, 50 Hz Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pedrollo is an Italian manufacturer of electric pumps for water, founded in 1974 by Silvano Pedrollo and based in San Bonifacio (VR), Italy. Its stated mission is to devise and implement cutting-edge solutions, driven by the desire to move water everywhere, for life. Seven Star LLC, an independent supplier in Muscat, quotes Pedrollo pumps against the model code and duty shown in the project specification.
Pedrollo pump families
The catalogue is organised into surface pumps, submersible pumps, borehole pumps, pressure groups (booster sets) and control panels with electronic protection devices. Surface pumps include EN 733 standardised centrifugal pumps, single and twin impeller centrifugal pumps, horizontal and vertical multistage pumps, self-priming pumps and peripheral pumps. Submersible lines cover sewage and drainage pumps, multistage submersibles for pressure increase and 3, 4, 5 and 6 inch borehole pumps. The manufacturer publishes 50 Hz and 60 Hz datasheets for most series.
Requesting a quote
Send the full model code from the nameplate, such as the series, frame and motor power, with the supply voltage and frequency, the liquid, its temperature and the required flow and head. For a replacement pump, a photo of the nameplate and the connection sizes help to confirm the match.
Related products
Frequently Asked Questions
It has two impellers working in series, which Pedrollo uses to reach up to 112 m head from a close-coupled pump of compact size.
The 50 Hz datasheet gives up to 450 l/min (27 m3/h), depending on frame and trim.
2CP 25/14, 25/16, 32/200, 32/210, 40/180 and 40/200, each with two or three trims lettered A, B or C.
Clean water and liquids that are chemically non-aggressive towards the pump materials, from -10 C to +90 C.
The datasheet states a maximum working pressure of 10 bar.

Reviews