Brand: Lovato Electric
Lovato DMG200 Three-Phase Digital Multimeter 4-Module DIN
Description
A 4-module DIN rail multimeter with a graphic LCD and true RMS
The Lovato DMG200 is a modular digital multimeter and power analyzer for three-phase systems up to 690 Vac phase to phase. It occupies four DIN rail modules (72 mm) and combines a 128 x 80 pixel graphic backlit LCD with true RMS measurement, continuous gapless sampling in a compact housing. The DMG200 is the basic version of the DMG family; the DMG210 adds an RS485 port.
The DMG200 measures a wide set of electrical parameters, including phase, line and system voltages, phase currents with the neutral current calculated, active, reactive and apparent power, power factor, frequency, harmonic distortion (THD) of voltage and current, maximum demand and energy counters.
Technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / series | Lovato Electric, DMG200/DMG210 |
| Order code | DMG200 (the DMG210 is the version with RS485) |
| Display | Graphic LCD, 128 x 80 pixels, white backlight, 4 grey levels |
| Languages | Texts for measurements, setup and messages in 5 languages |
| Auxiliary supply | 100 to 240 Vac / 110 to 250 Vdc; range 85 to 264 Vac / 93.5 to 300 Vdc |
| Power consumption | 3.5 VA; 1.2 W dissipation |
| Voltage inputs | Three-phase plus neutral; max. 690 Vac phase-phase (400 Vac phase-neutral) |
| Voltage measurement range | 20 to 830 Vac phase-phase; 10 to 480 Vac phase-neutral; 45 to 66 Hz and 360 to 440 Hz |
| Current inputs | 5 A rated through external CT; range 0.01 to 6 A; overload +20%, peak 50 A for 1 s |
| Current with CT | Up to 10,000 A primary |
| Method of measurement | True RMS |
| Accuracy | Voltage +/-0.5%; current +/-0.5% (0.1 to 1.1 In); power +/-1% f.s.; frequency +/-0.05% |
| Energy classes | Active class 1 (IEC/EN/BS 62053-21); reactive class 2 (IEC/EN/BS 62053-23) |
| Communication | None on the DMG200; the DMG210 has an isolated RS485 port |
| Connection | Single-, two- and three-phase with or without neutral; balanced three-phase systems |
| Insulation | Ui 690 Vac; Uimp 9.5 kV; 5.2 kV power frequency withstand |
| Terminals | Supply and voltage 0.2 to 4.0 mm2, 0.8 Nm; current inputs 0.2 to 2.5 mm2, 0.44 Nm |
| Operating / storage temperature | -20 to +60 C / -30 to +80 C; humidity below 90% |
| Protection degree | IP40 front, IP20 terminals; measurement class III; pollution degree 2 |
| Housing / weight | 4-module polyamide DIN rail housing; 0.294 kg |
Using the DMG200 in distribution panels
The multimeter is a good fit for main incomers, motor control centre feeders, generator and transformer monitoring and any point where the operator needs voltage, current, power factor and harmonic distortion on one screen. Highest, lowest and average values, maximum demand of current and power, asymmetric voltage and current readings and an hour counter are available for each page, and highest peaks are kept even when auxiliary power is removed.
The DMG200 has no communication port, so it is a local indication instrument; if the readings must reach a PLC, SCADA or energy management system, choose the DMG210 with RS485 instead. Setup is done from the front keyboard. The current inputs are for external 5 A current transformers; a Rogowski coil input is not provided on this model.
Selection notes
Select the CT ratio and class to suit the load and the accuracy needed, and use voltage transformers for medium-voltage systems. The DMG200 is a panel multimeter; where billing-grade metering is required, check Lovato’s dedicated energy meter range. Confirm the supply range of the auxiliary input, the wiring mode for your network and the communication settings (address, baud rate, parity) with the controls integrator before ordering.
Key features of the DMG200
- True RMS with continuous sampling: readings stay correct on distorted waveforms from drives, UPS systems and LED lighting, where average-responding meters under- or over-read.
- Wide measuring range: one model covers low-voltage networks up to 690 Vac phase to phase, so the same spare can be stocked for 400 V and 690 V switchboards.
- Harmonic indication: voltage and current THD on the display give a first warning of harmonic problems before capacitor banks or transformers overheat.
- Demand and peak memory: maximum demand and highest values are retained, which helps size feeders and check whether a breaker is close to its limit.
- Wide auxiliary supply: 100–240 Vac or 110–250 Vdc lets the meter run from the panel control voltage or a station battery.
- Compact 4-module housing: fits on the same DIN rail as breakers and relays, without a door cut-out.
Wiring and set-up guidance
Before energising, choose the wiring mode in the setup menu that matches the network: three-phase with neutral, three-phase without neutral, balanced three-phase, two-phase or single-phase. Enter the CT primary current so readings are shown in primary amperes, and if voltage transformers are used, enter their ratio too. Fit protective fuses on the voltage inputs and auxiliary supply, and always short-circuit CT secondaries with a shorting terminal block before removing the meter, since an open CT secondary can produce dangerous voltages. Observe the CT polarity (S1/S2) and the phase sequence; a reversed CT shows negative active power on that phase, which is the most common commissioning error.
Choosing current transformers
Pick a CT primary close to the expected full-load current so the meter works in the upper part of its range, where accuracy is best. A 5 A secondary is required. For energy readings that matter, a CT accuracy class of 0.5 or better is a sensible match for a class 1 meter; for indication only, class 1 is usually adequate.
Use in Oman and GCC panels
The operating range of −20 to +60 °C suits most indoor switchrooms in the region, including LV panels in substations, villas, commercial towers and industrial plants. Where panels sit in hot, unventilated rooms or outdoor feeder pillars, the internal temperature should still be checked against this limit. The IP40 front protects against solid objects but not against water or fine dust, so mount the meter behind a closed panel door in dusty areas such as quarries and construction sites. On generator-supplied sites, the frequency, voltage asymmetry and THD pages are useful to check generator loading and power quality. Typical uses include monitoring main incomers, AC chiller feeders, pump MCCs and solar PV interconnection boards.
What to include in your RFQ
- Model DMG200, or DMG210 if RS485 communication is needed.
- Quantity and network voltage (phase to phase).
- CT ratio, and whether matching CTs should be quoted.
- Auxiliary supply voltage available in the panel.
Documents and quotation
The attached I269 instruction manual covers the DMG200 and DMG210 display pages, setup menu, wiring diagrams, communication parameters and mechanical drawing; the catalogue chapter gives the full range of DMG models and expansion options. When requesting a quotation for the DMG200, send the quantity, CT ratio and supply voltage. See also Automation Accessories and the Carlo Gavazzi single-phase energy analyzer EM111.
Datasheets & Documents
- Datasheet Lovato DMG200 / DMG210 instruction manual (I269 GB) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is an Italian manufacturer of low voltage electrical devices for industrial applications, founded in 1922 in Bergamo and still family owned. Seven Star LLC, an independent supplier in Muscat, quotes Lovato Electric contactors, motor protection circuit breakers, generator controllers and power factor controllers for control panels, motor starters and stand-by power systems.
Motor control, protection and energy management
The Lovato Electric catalogue covers contactors and motor protection circuit breakers, thermal overload relays, soft starters, pushbuttons and signalling, switch disconnectors, time and monitoring relays, energy meters, power factor controllers and engine and generator controllers. Each catalogue page links its instruction sheet, leaflet and declarations of conformity.
Ordering Lovato Electric products
Send the full order code, coil or supply voltage, quantity and any approval needed for the project. With the order code, the matching version can be checked against its documentation before a quotation is issued.
Related products
Frequently Asked Questions
No. The RS485 port is only on the DMG210; the DMG200 is the version without communication.
It uses a 4-module DIN rail housing, 72 mm wide.
Up to 690 Vac phase to phase directly, with a measurement range of 20 to 830 Vac.
External current transformers with a 5 A secondary.
Voltage and current +/-0.5%, power +/-1% of full scale, active energy class 1.