Brand:

ABB ACS880-01-065A-5 ACS880-01 30 kW Frame R5 AC Drive

Description

30 kW ABB ACS880-01-065A-5 drive for process and machine control

A 65 A rating, a frame R5 housing and a 380 to 500 V input define the ABB ACS880-01-065A-5. ABB positions the ACS880 single drive for demanding industrial duty and offers direct torque control in its primary control program.

Typical uses in oil, gas, water and fabrication plants include centrifugal pumps, extruders, hoists and test benches. The drive ships as IP21 (UL Type 1) unless a plus code selects another construction.

Technical specifications

Parameter Specification
Type code ABB ACS880-01-065A-5
Series ACS880-01 wall-mounted single drive
Frame size R5
Supply voltage 3-phase 380 to 500 V, +10% / -15%, 50/60 Hz
Nominal output current 65 A
Nominal motor power (400 V) 30 kW
Light / heavy duty (400 V) 62 A / 30 kW and 52 A / 22 kW
Maximum output current 104 A
Input current (400 V) 65 A
Rating at 500 V 65 A, 37 kW; light duty 62 A / 37 kW; heavy duty 52 A / 30 kW
UL rating at 480 V 50 hp light duty, 40 hp heavy duty
Standard IP21 enclosure 203 x 732 x 274 mm, 22.8 kg
IP55 option +B056 203 x 886 x 344 mm, 23.4 kg
Typical loss / air / noise 715 W, 280 m3/h, 64 dB(A)
gG fuse 100 A, OFAF000H100
aR fuse option 125 A, 170M1568
UL class T fuse JJS-90
Copper cable 3×35 mm2 (UL 4)
Motor cable, maximum 300 m
Output frequency 0 to 598 Hz
Operating temperature -15 to +55 C with derating; up to 4000 m
Safety and panel Safe torque off, ACS-AP-W panel, coated boards, DC choke

What to size around 065A A

Overload capability is expressed through duty classes. Here the heavy-duty class carries 52 A (22 kW), the light-duty class 62 A (30 kW) and nominal use 65 A (30 kW), all at 400 V.

The -5 voltage code also covers 480 V and 500 V networks: 65 A and 37 kW nominal at 500 V, or 50 hp light duty and 40 hp heavy duty by the UL table at 480 V.

Frame R5 weighs 22.8 kg in IP21 form and measures 203 mm wide, 732 mm high and 274 mm deep including the cable entry box. Cooling air demand is 280 m3/h; typical losses reach 715 W, which the cabinet or room must carry away.

Fusing options are 100 A gG (OFAF000H100), 125 A aR (170M1568) or UL class T JJS-90. The IEC copper cable entry is 3×35 mm2 and the UL conductor is 4 AWG-kcmil. This frame has no brake chopper as standard; ABB lists the +D150 brake chopper as a factory option.

Keep the motor cable within 300 m (frame R5). The drive works on TN and IT networks, with a 65 kA short-circuit rating when protected by the listed fuses.

Reading the ACS880-01-065A-5 order code

In ACS880-01-065A-5, ACS880 is the series, 01 the wall-mounted single drive, 065A the size and -5 the voltage range. Plus codes follow: +B056 gives IP55, +E200 and +E202 select EMC filters, +D150 adds a brake chopper and +C131 adds vibration dampers. Quote every plus code you need.

Selection checks for the 065A-5 drive

Begin with the motor nameplate and the load. Compare the motor full-load current with the duty class that matches the application: a centrifugal pump or fan usually fits a light-duty rating, while a hoist, extruder or conveyor that starts under load points toward the heavy-duty figure. Confirm the supply voltage at site, the network earthing system and the prospective short-circuit level, and decide whether the application regenerates energy that would need braking.

Next look at the installation: wall space in a panel or plant room, cable routes, the length of the motor cable, and whether EMC requirements on site call for one of the filter plus codes listed above. Listing these points in the enquiry avoids ordering a drive that needs changes after it arrives.

Installation and commissioning

Mount the drive vertically on a solid, non-flammable surface with the clearances given in the ABB hardware manual so cooling air can flow freely. Use the fuse types listed for this frame, size cables for the actual current and route the motor cable separately from control and signal cabling. Shielded motor cable with correct earthing at both ends helps reduce interference with nearby instruments.

Before first energisation, check insulation resistance of the motor and cable as the manual instructs, verify all terminations and confirm that the safe torque off circuit is wired as the safety design requires. Use the control panel start-up assistant to enter motor data, run the motor identification routine where the mechanics allow it, and then set ramps, limits and the control source. Save a parameter backup once the drive runs correctly and record it with the loop documentation.

Heat, dust and humidity in Omani plant rooms

The typical losses and cooling air figures in the table become critical in Oman and the GCC, where summer ambient temperatures in outdoor kiosks and unventilated rooms can approach or exceed the range in which the drive runs without derating. Size room ventilation or panel cooling for the heat the drive and other equipment release, and keep inlet air as clean and cool as practical. Avoid placing the drive where hot exhaust from other equipment feeds its intake.

Fine dust settles on heat sinks and reduces cooling, and humid coastal air can lead to condensation when equipment cools overnight. Filtered ventilation, sealed cable entries and the IP55 construction option are worth considering for dusty or damp sites, and the coated boards listed in the specification help in harsh atmospheres.

Routine maintenance

Follow the ABB preventive maintenance schedule for the frame. In practice that means periodic cleaning of air paths, checking that cooling airflow is unobstructed, re-tightening power terminals at the recommended intervals and reviewing the fault and event logs for recurring warnings. Keep a copy of the current parameter set so a replacement drive can be configured quickly if needed.

Documents and quotation

The catalogue attached to this page and the abb.com record for ACS880-01-065A-5 document the type. Neighbouring products sit under AC Drives, with the family overview on the ACS880-01 page.

Confirm voltage band, frame, plus codes and control panel with us before ordering. Seven Star LLC is an independent supplier in Muscat; stock and lead time are stated in the quotation.

Datasheets & Documents
  • PDF Catalog ABB ACS880 single drives catalog (3AUA0000098111) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.

Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.

ABB product families on this page

Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.

Where ABB instruments and drives are used

Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.

Ordering ABB parts: what we need

For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.

Frequently Asked Questions

What does 065A mean in ACS880-01-065A-5?
It is ABB's size code for this ACS880-01 type, equal to 65 A nominal output current in the -5 (380 to 500 V) voltage range.
Which frame size is ACS880-01-065A-5?
ABB lists it as frame R5. The IP21 enclosure is 203 mm wide, 732 mm high, 274 mm deep and weighs 22.8 kg.
What fuse does the manual give for ACS880-01-065A-5?
A 100 A gG fuse of ABB type OFAF000H100; the aR alternative is Bussmann 170M1568 at 125 A, and UL installations use JJS-90.
Does ACS880-01-065A-5 include a brake chopper?
Not as standard in frame R5. ABB lists +D150 as the brake chopper option for this frame.
What should I send for a ACS880-01-065A-5 quotation?
The full type code with plus codes, quantity, supply voltage, motor current, duty cycle and enclosure requirement. Seven Star LLC confirms availability and lead time with the quotation.