Invertek Drives Optidrive P2 Industrial Vector Drive

Invertek Optidrive P2: 0.75-250 kW vector VFD, 200-600 V, IP20/IP55/IP66, STO SIL 2, 150 % overload. Technical data and RFQ.

15 People watching this product now!
Description

High-performance vector drive for demanding machinery

The Invertek Drives Optidrive P2 is a high-performance variable frequency drive for industrial machines such as cranes, compressors, winders, extruders, mixers and process lines. It covers 0.75 to 250 kW (1 to 400 HP) on supplies from 200 to 600 V, single-phase and three-phase. Vector control gives up to 200 % torque from zero speed, and the drive allows 150 % overload for 60 seconds, which suits loads with high starting torque. It is available in IP20, IP55 and IP66 versions, so it can be fitted into a cabinet or mounted directly in the plant.

The data below is taken from the Invertek Drives Optidrive P2 user guide and brochure.

Technical specifications

Parameter Specification
Manufacturer Invertek Drives Ltd, Welshpool, United Kingdom
Series Optidrive P2
Power range 0.75 to 250 kW (1 to 400 HP)
Supply voltages 200 to 600 V, single-phase and three-phase variants
Frame sizes 2 to 8
Enclosures IP20 and IP55 up to 250 kW; IP66 up to 30 kW
Model code ODP-2-…
Example rating 380-480 V three-phase: 0.75 kW at 2.2 A up to 250 kW at 480 A
Overload 150 % for 60 seconds
Control Vector control with up to 200 % torque from zero speed
Safety Safe Torque Off, SIL 2 per EN 62061
Built-in communications Modbus RTU and CANopen
Optional communications PROFIBUS, DeviceNet, EtherNet/IP, PROFINET, EtherCAT; encoder feedback cards
Operating temperature IP20: minus 10 to plus 50 degrees C; IP55 and IP66: minus 10 to plus 40 degrees C, up to 50 degrees C with derating
Altitude Up to 1,000 m for UL; up to 4,000 m with derating

Control and connectivity

The P2 supports closed-loop and open-loop vector control of induction and permanent magnet motors, with optional encoder cards for applications that need exact speed or position. Modbus RTU and CANopen are on board. Option modules add the common industrial Ethernet and fieldbus networks, so the drive can be integrated into most PLC systems. The Optistick Smart tool stores and copies parameter sets, and application macros help to shorten commissioning.

Environment and compliance

IP55 and IP66 drives are intended for 3S3 and 3C3 environmental classes and IP20 drives for 3S2 and 3C2, as stated in the user guide. Derating applies at higher temperatures or altitude. The Safe Torque Off input is built in and designed to the SIL 2 level of EN 62061, so many machines no longer need an external safety contactor to prevent unexpected torque on the motor.

For cranes and hoists, the combination of high torque at zero speed, braking support and the safety input is relevant, while for compressors and extruders the overload rating and the ability to run at low speed under load matter more. When selecting a size, base the choice on the motor current and the duty cycle and not only on kilowatts, and remember that the overload rating is time limited. A drive for a continuous heavy duty may need to be one size larger than the motor power suggests.

How the Invertek Optidrive P2 works

A variable frequency drive converts the fixed-frequency supply into a variable voltage and frequency for an AC motor. The Optidrive P2 first rectifies the incoming supply to a DC bus, and then an inverter builds the output waveform with fast switching. In vector control the drive models the motor and controls torque and flux separately. This is why it can give up to 200 percent torque from zero speed and hold speed accurately under changing load. The drive can control induction motors and permanent magnet motors, in open loop or with encoder feedback.

Where the Optidrive P2 is used

  • Cranes and hoists that need torque at zero speed
  • Compressors and winders
  • Extruders and mixers
  • Process lines and conveyors
  • Pumps and fans where speed control saves energy
  • Machines mounted in the plant, with the IP55 or IP66 versions

Selection checklist for the Optidrive P2

  • Motor power and full-load current, against the drive rating in amps
  • Supply voltage and phases, from 200 to 600 V
  • Overload need, 150 percent for 60 seconds
  • Enclosure, IP20 for cabinets, IP55 or IP66 for wall mounting
  • Ambient temperature and the need for derating
  • Altitude above 1,000 m
  • Fieldbus needed, such as PROFIBUS, PROFINET, EtherNet/IP, DeviceNet or EtherCAT
  • Encoder feedback for exact speed or position

Installation, commissioning and maintenance notes

Mount the drive on a flat surface with the clearances for airflow that the user guide gives. Use screened motor cable and ground the screen at both ends, and keep control wiring away from power cables. Enter the motor nameplate data and run the auto-tune before the first start. Check the direction of rotation with the motor uncoupled. Clean the heat sink and the fans at planned intervals, and keep a copy of the parameter set.

Requesting a quotation for the Invertek Optidrive P2

Please send the model code, the motor data, the supply voltage, the enclosure and the options. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

Optidrive P2 safety function

The drive has Safe Torque Off to SIL 2 under EN 62061. It removes the torque from the motor without disconnecting the power, which suits machines with guards and emergency stops.

Optidrive P2 communications

Modbus RTU and CANopen are built in. Option modules add the common Ethernet and fieldbus networks.

Optidrive P2 parameter tools

The Optistick Smart tool stores and copies parameter sets. Application macros shorten commissioning.

Optidrive P2 frame sizes

The range runs from frame size 2 to frame size 8. A 380-480 V three-phase drive of 0.75 kW draws 2.2 A, and a drive of 250 kW draws 480 A.

Drive records for Optidrive P2

Keep the model code, the parameter file, the motor data and the date of commissioning with the machine records.

Documents and quotation

The attached PDF is the official Invertek Drives user guide. For a quotation send the supply voltage, motor power and current, duty cycle, braking needs, fieldbus and enclosure rating. Related drives are listed in AC Drives, for example the Danfoss FC 102.

Datasheets & Documents
  • PDF User Guide Invertek Drives Optidrive P2 user guide V3.10 Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Invertek Drives designs and manufactures variable frequency drives at its global headquarters in Welshpool, Wales, in the United Kingdom. The company is part of Sumitomo Heavy Industries and holds ISO 9001 certification. Seven Star LLC lists selected Optidrive models with links to the official Invertek user guides.

Optidrive families

The Optidrive E3 is a compact general-purpose drive in IP20 and IP66 versions, with a variant for single-phase output motors. The Optidrive P2 is an industrial vector drive up to 250 kW, and the Optidrive Eco range is aimed at HVAC and pumping applications with built-in building and pump control functions.

Features such as sensorless vector control, Safe Torque Off, built-in fieldbus communication and low-harmonic design vary by family, so each product page lists the points that apply to that model and the limits of its environment.

Documents and quotation

Every Invertek page on this site links to the user guide with ratings, model codes and environmental limits. Send the supply voltage, motor data and enclosure rating with your request, and Seven Star LLC will prepare a quotation from Muscat, Oman.