Brand: Rosemount
Rosemount 848T High Density Temperature Transmitter
Description
Overview
Rosemount 848T is a high-density, multi-input temperature transmitter from Emerson that consolidates as many as eight independent temperature measurement points into a single field device, dramatically reducing the number of transmitters, junction boxes, and cable runs required for large equipment such as tanks, reactors, heat exchangers, and rotating machinery. Available in FOUNDATION Fieldbus and WirelessHART versions, the Rosemount 848T accepts RTD, thermocouple, ohm, millivolt, and 4–20 mA inputs, giving instrumentation engineers a single flexible platform for mixed sensor types on the same asset.
In Oman and the GCC, Seven Star LLC proudly supplies the Rosemount 848T High Density Temperature Transmitter to refineries, LNG facilities, power plants, and process manufacturers across the Sultanate of Oman and the wider GCC.
Measurement Principle
The Rosemount 848T operates as a multiplexed input module, sequentially scanning up to eight sensor channels and converting each raw RTD, thermocouple, ohm, or millivolt signal into a linearized, temperature-compensated digital reading. Each input channel is independently configurable for sensor type, range, and alarm behavior, so a single transmitter can simultaneously service a mix of thermocouples on a furnace and RTDs on adjacent piping without requiring separate devices for each sensor technology.
Because the readings are transmitted digitally over FOUNDATION Fieldbus or WirelessHART rather than as individual 4–20 mA loops, the Rosemount 848T eliminates the marshalling cabinets, multi-core cabling, and I/O card real estate that traditional point-to-point wiring would demand for the same number of measurement points. Built-in diagnostics flag open-circuit, short-circuit, and out-of-range sensor conditions on a per-channel basis, so a single failed thermocouple does not compromise visibility of the other seven measurement points on the same device.
Engineering Design of the Rosemount 848T
The Rosemount 848T is built in a field-hardened enclosure suitable for outdoor and hazardous-area installation, with a rail-mount or head-mount form factor depending on the model configuration selected. The wireless variant integrates Emerson’s SmartPower module, which is engineered to deliver up to ten years of maintenance-free operation from a single power module, removing the need for external wiring or battery replacement visits on hard-to-access equipment such as tank farms and remote rotating assets.
Terminal blocks are clearly labeled per input channel to simplify field wiring and troubleshooting, and the transmitter supports standard configuration tools including AMS Device Manager and, for the wireless model, Emerson’s Smart Wireless Gateway for integration into an existing WirelessHART mesh network. The compact multi-input architecture means a single junction box location can now serve an entire vessel or skid, simplifying both the original installation and any future sensor additions.
Key Features
The Rosemount 848T reduces wiring complexity and device count wherever multiple temperature points need to be monitored from one location.
- Up to eight independent input channels accept RTD, thermocouple, ohm, millivolt, and 4–20 mA sensor signals on a single transmitter.
- Available in FOUNDATION Fieldbus and WirelessHART versions to match wired digital bus or wireless mesh network architectures.
- Per-channel diagnostics detect open-circuit, short-circuit, and sensor drift conditions without affecting the other measurement channels.
- SmartPower module on the wireless variant supports up to ten years of maintenance-free, battery-based operation.
- Consolidating multiple sensors into one device significantly reduces junction boxes, marshalling cabinets, and cable tray requirements.
- Compatible with AMS Device Manager and Smart Wireless Gateway for centralized configuration and network management.
- Field-hardened enclosure supports installation in hazardous-area classified zones common to oil, gas, and petrochemical plants.
- Mixed sensor-type support allows thermocouples and RTDs to be monitored from the same transmitter on a single asset.
Industrial Applications
The Rosemount 848T is widely applied on large storage tanks, distillation columns, heat exchangers, and rotating equipment bearings where multiple temperature points must be monitored across a single piece of equipment. In Oman’s LNG, refining, and power generation sectors, the transmitter is used to consolidate tank-farm skin thermocouples, reactor multi-point profiles, and turbine bearing RTDs into a fraction of the field devices a traditional single-input architecture would require, cutting both capital cost and long-term maintenance burden.
In Oman and the GCC, Seven Star LLC distributes the Rosemount 848T to EPC contractors and plant operators throughout the Sultanate of Oman and the broader GCC, including projects in the Sohar and Salalah industrial and free zones. Our technical staff in Muscat help engineering teams select the right channel count, sensor mix, and Fieldbus or Wireless configuration for each application.
Technical Specifications
The table below summarizes the core specifications of the Rosemount 848T high density temperature transmitter as published in Emerson’s official product documentation.
| Parameter | Specification |
|---|---|
| Model | Rosemount 848T |
| Input Channels | Up to 8 (FOUNDATION Fieldbus); up to 4 configurable inputs (WirelessHART) |
| Supported Sensor Types | RTD, thermocouple, ohm, millivolt, and 4–20 mA inputs |
| Communication Protocol | FOUNDATION Fieldbus or WirelessHART |
| Power Options | Fieldbus bus-powered; SmartPower module for wireless variant |
| Diagnostics | Per-channel open-circuit, short-circuit, and out-of-range detection |
| Configuration Tools | AMS Device Manager; Smart Wireless Gateway (wireless variant) |
| Enclosure | Field-hardened housing rated for outdoor and hazardous-area installation |
| Mounting | Rail-mount or head-mount depending on configuration |
Request a Quote for Rosemount 848T
Seven Star LLC invites instrumentation engineers, EPC contractors, and plant maintenance teams across Oman and the GCC to submit a formal request for quotation for the Rosemount 848T High Density Temperature Transmitter. In Oman and the GCC, we supply on request, provide the Emerson technical datasheet on request, and connect customers directly with our instrumentation division for channel-count sizing, Fieldbus or Wireless network planning, and hazardous-area certification guidance.
Browse the full Rosemount range or see more Temperature Instrumentation products supplied by Seven Star LLC in Oman and the GCC.
Datasheets & Documents
- Datasheet Rosemount 848T Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
The Rosemount 3051 is one of the most frequently specified pressure transmitters in process plants, and it sits at the center of this listing. Rosemount, a measurement brand that dates from 1956 and has its home in Shakopee, USA, covers pressure, temperature, level and flow with instruments identified by a model string on the nameplate.
Seven Star LLC is an independent supplier listing Rosemount pressure transmitters, level instruments, temperature transmitters, flowmeters and analytical sensors for sites in Oman and the GCC.
Rosemount product families on this page
Pressure includes the 3051 in its variants (3051T in-line, 3051L for liquid level, 3051CF DP flowmeter and the 3051SMV MultiVariable transmitter), the 2051 and 1199 diaphragm seal systems. Level instruments are the 3300 guided wave radar, the 5408 non-contacting radar and the 2120 vibrating fork switch. Temperature is covered by the 248 and 644 head mount transmitters and the 848T high density transmitter for multiple sensor inputs. The 8800D vortex flowmeter and the 702 wireless discrete transmitter are also listed, along with liquid analysis sensors.
Where Rosemount instruments are used
These are standard instruments in oil and gas production, refining, petrochemical, power and water plants. Typical duties are line and vessel pressure, differential pressure flow across orifice plates, tank and separator level and interface, and temperature measurement on pipes, reactors and rotating equipment.
Ordering Rosemount transmitters: what we need
Send the complete model string and the serial number from the nameplate; a photo is ideal. Every character of the string selects something: range, output, materials of the isolating diaphragm and flange, process connection, housing, approval and options. If you are specifying a new point, give the measured variable and span, process fluid, pressure and temperature, connection, output (4-20 mA HART, FOUNDATION Fieldbus or wireless), display and hazardous area approval. For remote seals add flange size, rating and capillary length.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
Related products
Frequently Asked Questions
The Rosemount 848T FOUNDATION Fieldbus version supports up to eight independent temperature input channels, while the WirelessHART version supports up to four configurable inputs, all from a single transmitter.
The transmitter accepts RTD, thermocouple, ohm, and millivolt inputs, plus 4–20 mA signals on the wireless variant, and different channels can be configured for different sensor types simultaneously.
The WirelessHART Rosemount 848T uses Emerson’s SmartPower module, engineered to support up to ten years of maintenance-free operation, which removes the need for field wiring or frequent battery replacement.
Yes, the wireless version joins an existing WirelessHART mesh network and is managed through Emerson’s Smart Wireless Gateway, while the Fieldbus version integrates directly with a FOUNDATION Fieldbus segment and AMS Device Manager.
Yes, Seven Star LLC supplies Rosemount products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.