Brand:

Sitelab UVF-Trilogy GRO Analyzer

Description

Overview

The Sitelab UVF-Trilogy GRO Analyzer (Model No. 7200-004-GRO) is a benchtop ultraviolet fluorescence instrument dedicated to gasoline range organics screening across the C6–C10 carbon range, capturing BTEX compounds and the other volatile petroleum hydrocarbons that characterize light-refined fuel contamination. Seven Star LLC supplies the Sitelab UVF-Trilogy GRO Analyzer to environmental consultancies, remediation contractors, and fuel terminal operators across Oman and the wider GCC region who need same-day gasoline range hydrocarbon data on soil or water samples without shipping to an outside laboratory. Every Sitelab UVF-Trilogy GRO Analyzer arrives factory calibrated using Sitelab’s own GRO reference standards, so a technician can begin measuring samples immediately after the unit is unboxed and connected to power. As the official authorized partner and exclusive regional representative for Sitelab, Seven Star LLC proudly supplies the Sitelab UVF-Trilogy across Oman and the wider GCC, backed by genuine stock, manufacturer-standard calibration data, and responsive local technical support.

Working Principle

The Sitelab UVF-Trilogy GRO Analyzer excites a solvent-extracted sample with an ultraviolet LED tuned to the GRO module’s specific wavelength and optical filter, then measures the resulting fluorescence of the aromatic hydrocarbons present at gasoline-range volatility. The instrument reports a minimum detection limit of 0.5 ppm across the C6–C10 range, and results from the Sitelab UVF-Trilogy GRO Analyzer compare well to EPA Method 8015, VPH methods, and other laboratory TPH-GRO gas chromatography test methods, giving field teams a fast screening tool that correlates meaningfully with confirmatory lab analysis. Because gasoline range organics evaporate and weather faster than heavier diesel or oil fractions, rapid on-site measurement with the GRO Analyzer captures contamination signatures that could otherwise be lost by the time a sample reaches an off-site laboratory.

Engineering Design

The Sitelab UVF-Trilogy GRO Analyzer shares the same rugged benchtop chassis as the rest of the Trilogy platform: an intuitive touch screen interface, storage for up to 18 calibrations in onboard memory, and a snap-in UV module bay so the GRO module can be combined with EDRO, TPH Oil, or PAHs modules on a single instrument as a project’s scope broadens. Every unit ships with a glass sample cuvette and a solvent dispenser bottle included, with spare quartz cuvettes available separately under part number QCUV-10MM. For field deployments beyond Seven Star’s client sites in Oman, the optional heavy-duty waterproof field case (part number 7200-UVFCASE) adds a rechargeable 120V battery so the Sitelab UVF-Trilogy GRO Analyzer can travel to a fuel depot, tank farm, or underground storage tank removal site.

Key Features

The Sitelab UVF-Trilogy GRO Analyzer detects BTEX and other volatile gasoline-range hydrocarbons with a minimum detection limit of 0.5 ppm, delivering low-ppm sensitivity without requiring gas chromatography equipment on site. Calibration kits are matrix-specific—part number CAL-025M is methanol-based for soil analysis while CAL-025H is hexane-based for water analysis, each containing five calibration standards—so the GRO Analyzer can be tuned precisely to the sample matrix under investigation. The touch screen interface walks operators through sample measurement, calibration, and mode selection in a few taps, and results are available in minutes rather than the days a laboratory turnaround typically requires.

Industrial Applications

Seven Star positions the Sitelab UVF-Trilogy GRO Analyzer for gasoline release investigations, jet fuel and heating oil contamination screening, diesel and other light-refined petroleum contamination assessments, and underground storage tank (UST) removal site closure sampling. Oman’s fuel retail network, aviation fueling depots, and the GCC’s dense underground storage tank infrastructure all generate a steady need for fast, defensible gasoline range hydrocarbon data, and the GRO Analyzer lets environmental consultants triage which soil or water samples genuinely require confirmatory VPH or GC laboratory analysis before committing project budget to outside testing. Marine bunkering terminals and vehicle fueling stations across the region likewise rely on the Sitelab UVF-Trilogy GRO Analyzer to screen for gasoline-range leaks during routine tank integrity monitoring.

SpecificationDetail
Model Number7200-004-GRO
Detection TechnologyUltraviolet fluorescence (UVF)
Target Analyte RangeGasoline range organics / BTEX, C6–C10
Minimum Detection Limit0.5 ppm
Sample TypesSoil and water; gasolines, jet fuels, heating oils, diesel
Reference MethodsCorrelates with EPA Method 8015, VPH methods, and other TPH-GRO GC methods
Calibration KitsCAL-025M (methanol, soil) and CAL-025H (hexane, water), five standards each
Calibration StorageUp to 18 calibrations in onboard memory
InterfaceIntuitive touch screen
Sample AccessoriesGlass cuvette and solvent dispenser bottle included
PlatformUVF-Trilogy benchtop analyzer with snap-in GRO UV module
Optional Field CasePart No. 7200-UVFCASE, waterproof case with rechargeable 120V battery

Sites where gasoline-range contamination is only part of the picture can pair the Sitelab UVF-Trilogy GRO Analyzer with additional EDRO, TPH Oil, or PAHs modules on the same chassis, or step up to the four-module Fingerprinting Analyzer for full forensic characterization of a mixed petroleum release. Seven Star’s technical team helps clients in Oman and across the GCC select the right module configuration before committing to a purchase, so the instrument continues to match the project’s testing needs as they evolve over time. As the officially authorized partner for Sitelab, Seven Star LLC distributes the Sitelab UVF-Trilogy to laboratories, industrial facilities, and research institutions throughout Oman, Muscat, and the Sohar and Salalah economic zones, backed by regional stock and manufacturer-standard support.

Because gasoline range hydrocarbons volatilize quickly once a sample is exposed to air, laboratories often report lower TPH-GRO concentrations than what was actually present in the ground at the time of sampling, simply due to loss during shipping and storage. Running the Sitelab UVF-Trilogy GRO Analyzer on site captures a reading close to the true in-situ concentration, which is particularly valuable when regulatory decisions in Oman or elsewhere in the GCC hinge on whether a gasoline release exceeds a specific screening threshold. Consultants who pair on-site GRO screening with periodic confirmatory laboratory samples typically end up with a more defensible overall data set than relying on off-site analysis alone.

Request a Quote for Sitelab UVF-Trilogy GRO Analyzer

Seven Star LLC supplies the Sitelab UVF-Trilogy GRO Analyzer and the complete family of Sitelab UVF hydrocarbon test equipment to environmental consultants, remediation contractors, and oil and gas operators across Oman and the wider GCC region. For pricing, calibration kits, or technical guidance on selecting the right UVF module configuration for your gasoline-range contamination project, contact our engineering team for a tailored quotation and application support. As the authorized partner for Sitelab in Oman and the GCC, Seven Star LLC guarantees genuine Sitelab UVF-Trilogy stock with full manufacturer warranty and regional technical support.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Sitelab UVF-Trilogy GRO Analyzer”

Your email address will not be published.Required fields are marked *

About brand
Sitelab Corporation is a U.S.-based manufacturer specializing in portable and benchtop ultraviolet fluorescence (UVF) instruments for on-site petroleum hydrocarbon testing in soil, sediment, and water. Sitelab's UVF technology gives environmental consultants, remediation contractors, and oil and gas operators a fast, field-deployable alternative to laboratory gas chromatography, with results that correlate closely with EPA Methods 1664, 9071B, and standard GC/GC-MS test methods. The product line spans the rugged handheld UVF-500D screening analyzer to the benchtop UVF-Trilogy platform, whose interchangeable UV modules target gasoline-range, diesel-range, PAH, and total petroleum hydrocarbon contamination for underground storage tank closures, spill response, produced water compliance, and Phase II environmental site assessments. Seven Star LLC supplies genuine Sitelab hydrocarbon analyzers and calibration standards to environmental and oil and gas operators across Oman and the wider GCC region.

Frequently Asked Questions

What carbon range does the Sitelab UVF-Trilogy GRO Analyzer detect?
The GRO Analyzer (Model 7200-004-GRO) detects gasoline range organics and BTEX compounds from C6 to C10, with a minimum detection limit of 0.5 ppm.
What sample types can the GRO module analyze?
The GRO module analyzes both soil and water samples, and is suited to gasolines, jet fuels, heating oils, diesel, and other light-refined petroleum contamination.
How do GRO Analyzer results compare to laboratory methods?
Results compare well to EPA Method 8015, VPH methods, and other laboratory TPH-GRO gas chromatography test methods.
Which calibration kits does the GRO Analyzer use?
Part number CAL-025M is a methanol-based kit for soil analysis and CAL-025H is a hexane-based kit for water analysis, each containing five calibration standards.
Is Seven Star LLC an authorized representative for Sitelab products?
Yes, Seven Star LLC is the officially authorized partner and exclusive regional representative for Sitelab, supplying genuine Sitelab UVF-Trilogy with full manufacturer warranty and technical support across Oman and the GCC.