BARTEC Hygrophil HCDT-5985-72 Hydrocarbon Dew-Point Analyzer
Product Overview
The BARTEC Hygrophil HCDT-5985-72 is a hydrocarbon dew-point analyzer based on the chilled mirror principle, designed for continuous measurement of hydrocarbon dew point in natural gas and other hydrocarbon gas streams. The instrument is part of the Hygrophil HCDT series of measuring systems for gas quality monitoring.
The analyzer uses an optical chilled mirror sensor that cools a mirror surface until condensation of hydrocarbons is detected, providing a direct physical measurement of the dew point. The system includes a sensor housing (type HCDT-5673 sensor) and the SCS 5985-72 analyzer unit, which controls the measurement and provides the outputs.
Key Features
- Chilled mirror hydrocarbon dew-point measurement for natural gas
- Direct physical measurement principle with optical detection
- Calibrated range: -20 C to +5 C dew point
- Cooling capacity down to 35 K below ambient
- Three analog 4-20 mA outputs for process integration
- Fully automatic measurement cycle
- Proven BARTEC gas quality technology
Technical Specifications
| Model | Hygrophil HCDT-5985-72 (with HCDT-5673 sensor) |
|---|---|
| Principle | chilled mirror, optical condensation detection |
| Calibrated range | -20 C to +5 C |
| Cooling | down to 35 K below ambient temperature |
| Outputs | three 4-20 mA analog outputs |
| Application | natural gas hydrocarbon dew point |
| Manufacturer | BARTEC Benke GmbH |
Applications
The HCDT is used for continuous hydrocarbon dew-point monitoring in natural gas transmission and distribution networks, LNG and gas processing plants, custody transfer stations and gas quality measurement systems, protecting pipelines from condensate formation.
Ordering and Selection
When selecting the BARTEC Hygrophil HCDT analyzer, confirm the sensor housing, cooling capacity and output configuration, because each Hygrophil HCDT analyzer is built for a specific gas quality monitoring duty. The HCDT-5985-72 version includes the chilled mirror sensor system, and the selected Hygrophil HCDT must be matched to the gas pressure and dew-point range at your station. Our team can help you confirm that the Hygrophil HCDT analyzer you select is correct for your natural gas application, and
Maintenance and Support
The Hygrophil HCDT analyzer requires periodic sensor cleaning and calibration checks, and genuine spare parts are available through Seven Star LLC. Our team supports gas quality monitoring systems with the full range of Hygrophil HCDT spares, including mirror sensors and filters. Contact us for assistance with the Hygrophil HCDT analyzer, and we will confirm availability and pricing.
Industry Applications and Custom Support
The Hygrophil HCDT analyzer is trusted by operations and maintenance teams across gas networks and processing plants in Oman, the GCC and the wider Middle East region. Our customers select the HCDT analyzer for reliability, genuine quality and dependable supply. Seven Star LLC provides custom support including technical selection, quotation and after-sales assistance, and we regularly supply this analyzer as part of preventive maintenance programs and shutdown packages. Whether you need a single unit or a complete set for a project, our team supports procurement and inspection.
The Hygrophil HCDT analyser measures the hydrocarbon dew point of the natural gas, and the analyser provides the continuous measurement for the gas quality monitoring at the transmission stations.
The analyser is installed in the gas analysis shelter, and the measured value supports the dew point control of the gas pipeline.
The Hygrophil analyser measures the hydrocarbon dew point for the gas quality monitoring, and the unit is supplied with the sample system for the pipeline installation.
The analyser output is connected to the gas quality recorder of the station.
The BARTEC Hygrophil HCDT-5985-72 analyzer is the hydrocarbon dew point analyzer of the Hygrophil series, and the BARTEC Hygrophil HCDT-5985-72 analyzer is used at the gas transmission stations for the quality monitoring.
The BARTEC Hygrophil HCDT-5985-72 analyzer is selected for the gas quality cabinet, and the HCDT-5985-72 unit measures the dew point of the pipeline gas.
Why Seven Star LLC?
Seven Star LLC supplies genuine BARTEC gas analysis equipment to customers in Oman and the GCC. We verify model numbers and sensor configurations, supporting gas quality monitoring systems with genuine components.
Seven Star LLC maintains a regional inventory in Muscat and coordinates directly with manufacturers across Europe and Asia. Our engineers help you verify the exact model and revision before ordering, avoiding costly mismatches.
Request a Quote for BARTEC Hygrophil HCDT-5985-72 Hydrocarbon Dew-Point Analyzer
For the Hygrophil HCDT analyzer or any related control and instrumentation requirement, contact the Seven Star LLC team. Submit a formal inquiry through our RFQ page with your measurement range, connection and configuration, and our specialists will respond with a detailed commercial proposal and the official Hygrophil documentation.
Related Products
BARTEC is a German-based global leader in explosion protection and safety technology, specializing in measurement, control and analyzer systems for hazardous areas across oil & gas, chemical, pharmaceutical, energy and manufacturing industries. Founded in 1975 and headquartered in Bad Mergentheim, Germany, the company develops certified solutions for explosion-proof automation, trace heating, measurement systems and IIoT connectivity designed for tough industrial environments. With manufacturing sites around the world and over 50 subsidiaries, BARTEC provides highly reliable, globally certified products and tailored system solutions. Seven Star LLC supplies genuine BARTEC products for industrial and process equipment projects across Oman and the Middle East.

































Reviews